15 THERMAL UNIFORMITY SURVEY (TUS) OPTION
This option affects the way in which operator batch initiation occurs.
Section 4.3.10
contains a full de-
scription of batch recording and the user should refer to that section for details not contained here. The
option also incorporates the ‘Remote CJ block’ option, so channels 6, 12, 18 and so on are ‘reference’
channels used to measure the block temperature.
15.1 PRE CALIBRATION AND POST CALIBRATION ENABLE
If the TUS option is fi tted, two extra ‘tick boxes’ (‘Pre calibration’ and ‘Post calibration’) appear in the
Batch confi guration menu (fi gure 15.1).
Figure 15.1 Batch confi guration menu
Pre calibration
If this tick box is enabled, the operator is required to carry out an input adjust procedure before the batch
can be initiated.
Post calibration
If this tick box is enabled, the operator is required to carry out an input adjust procedure when the batch
is stopped.