7. Operational Test of the STICK LIMIT Caution Message
Detail Steps/Work Items
Key Items/References
(1)
Remove the pilot's seat.
Refer to Section 25-10.
(2)
Set the ELECT. MASTER to ON.
Refer to Section 24-00.
(3)
Set both power levers to IDLE.
To test the system in the de-activated
configuration.
(4)
Connect pin "A" on the printed circuit (PC)
board installed on the flap actuator assembly to
electrical ground.
Refer to Chapter 92 for the wiring
diagram of the variable elevator stop
(stick limiter).
(5)
The STICK LIMIT caution message must
appear on the G1000 PFD after 6 seconds.
(6)
Remove ground connection from pin "A".
(7)
Set both power levers above approx. 20 %.
To test the system in the activated
configuration.
(8)
Connect pin "D" on the printed circuit (PC)
board installed on the flap actuator assembly to
electrical ground.
Refer to Chapter 92 for the wiring
diagram of the variable elevator stop
("stick limiter").
(9)
The STICK LIMIT caution message must
appear on the G1000 PFD after 6 seconds.
(10)
Remove ground connection from pin "D".
(11)
Set the ELECT. MASTER to OFF.
Refer to Section 24-00.
(12)
Install the pilot's seat.
Refer to Section 25-10.
Summary of Contents for DA 42 NG
Page 933: ...AIRCRAFT DA 42 NG AMM Fuel Doc 7 02 15 Rev 4 28 TITLE Page 1 15 Mar 2018 CHAPTER 28 FUEL ...
Page 1459: ...AIRCRAFT DA 42 NG AMM Lights Doc 7 02 15 Rev 4 33 TITLE Page 1 15 Mar 2018 CHAPTER 33 LIGHTS ...
Page 1711: ...AIRCRAFT DA 42 NG AMM Doors Doc 7 02 15 Rev 4 52 TITLE Page 1 15 Mar 2018 CHAPTER 52 DOORS ...
Page 1853: ...AIRCRAFT DA 42 NG AMM Wings Doc 7 02 15 Rev 4 57 TITLE Page 1 15 Mar 2018 CHAPTER 57 WINGS ...
Page 2071: ...AIRCRAFT DA 42 NG AMM Engine Doc 7 02 15 Rev 4 72 TITLE Page 1 15 Mar 2018 CHAPTER 72 ENGINE ...
Page 2288: ......
Page 2320: ......
Page 2322: ......