AIRCRAFT
DA 42 NG AMM
Electrical Power
Doc # 7.02.15
Rev. 4
24-60-00
Page 101
15 Mar 2018
Trouble-Shooting
1. General
This table tells you how to trouble-shoot the DC electrical distribution system. It does not tell you about
the equipment. For faults on an item of equipment, or a system, refer to the applicable chapter. For
example, for no oil pressure indication, see Chapter 77 - ENGINE INDICATING. Make sure that there
is 28 V DC on both the LH MAIN BUS and the RH MAIN BUS and that the alternators are supplying
power.
If you find the trouble in column 1 do the repair given in column 3.
Trouble
Possible Cause
Repair
There is 28 V DC on the RH
MAIN BUS but not on the
AVIONICS BUS.
AV. MASTER switch set to
OFF.
MASTER CONTROL circuit
breaker not set.
AVIONICS BUS circuit breaker
not set.
Avionics master relay
defective.
A failure of the cables which
connect the AVIONICS BUS to
the RH MAIN BUS.
Set the AV. MASTER switch to
ON.
Set the MASTER CONTROL
circuit breaker.
Set the AVIONICS BUS circuit
breaker.
Replace the avionics master
relay.
Do a continuity test of the
cables. Refer to Chapter 92 for
the wiring diagrams.
Repair/replace defective
wiring.
Summary of Contents for DA 42 NG
Page 933: ...AIRCRAFT DA 42 NG AMM Fuel Doc 7 02 15 Rev 4 28 TITLE Page 1 15 Mar 2018 CHAPTER 28 FUEL ...
Page 1459: ...AIRCRAFT DA 42 NG AMM Lights Doc 7 02 15 Rev 4 33 TITLE Page 1 15 Mar 2018 CHAPTER 33 LIGHTS ...
Page 1711: ...AIRCRAFT DA 42 NG AMM Doors Doc 7 02 15 Rev 4 52 TITLE Page 1 15 Mar 2018 CHAPTER 52 DOORS ...
Page 1853: ...AIRCRAFT DA 42 NG AMM Wings Doc 7 02 15 Rev 4 57 TITLE Page 1 15 Mar 2018 CHAPTER 57 WINGS ...
Page 2071: ...AIRCRAFT DA 42 NG AMM Engine Doc 7 02 15 Rev 4 72 TITLE Page 1 15 Mar 2018 CHAPTER 72 ENGINE ...
Page 2288: ......
Page 2320: ......
Page 2322: ......