AIRCRAFT
Oxygen System
DA 42 NG AMM
Page 202
15 Mar 2018
35-10-00
Doc # 7.02.15
Rev. 4
3. Empty the Oxygen System
Detail Steps/Work Items
Key Items/References
(1)
Place airplane outside of hangar.
(2)
Open the canopy.
(3)
Check that the ON/OFF knob is in the OFF
position.
(4)
Plug in one connection tube in the pilot’s outlet
port. Plug in only the connection tube including
the flow meter needle valve assembly.
(5)
Pull ON/OFF knob in ON position and adjust the
needle valve to maximum flow.
(6)
Confirm that the outlet of the flow meter needle
valve assembly does not point not towards oil or
grease (engine).
(7)
The cylinder is depleted when the flow meter
ball shows no flow.