AIRCRAFT
DA 42 NG AMM
Oxygen System
Doc # 7.02.15
Rev. 4
35-00-00
Page 1
15 Mar 2018
CHAPTER 35
OXYGEN SYSTEM
1. General
This Chapter tells you about the optional continuous flow oxygen system installed in the DA 42 NG
airplane. This Chapter contains general, trouble-shooting and maintenance information on the system.
2. Description
This oxygen system supplies supplemental oxygen which is required in an altitude above 12,500 ft.
Each pilot or passenger can connect a mask or cannula to the oxygen system via four outlet ports. The
operation of the oxygen system is controlled via a single ON/OFF switch installed below the instrument
panel on the pilot’s side. Information concerning the endurance of the system, which is in direct relation
to the cylinder pressure, is indicated on a pressure gauge installed on the upper right side of the
instrument panel.
A pressure gauge is installed on the RH side of the instrument panel. This gauge shows the amount
of remaining oxygen by means of the current oxygen pressure in the cylinder. Two marks (REFILL=red
color and FULL=green color) show the limits within which the system can be operated.
Summary of Contents for DA 42 NG
Page 933: ...AIRCRAFT DA 42 NG AMM Fuel Doc 7 02 15 Rev 4 28 TITLE Page 1 15 Mar 2018 CHAPTER 28 FUEL ...
Page 1459: ...AIRCRAFT DA 42 NG AMM Lights Doc 7 02 15 Rev 4 33 TITLE Page 1 15 Mar 2018 CHAPTER 33 LIGHTS ...
Page 1711: ...AIRCRAFT DA 42 NG AMM Doors Doc 7 02 15 Rev 4 52 TITLE Page 1 15 Mar 2018 CHAPTER 52 DOORS ...
Page 1853: ...AIRCRAFT DA 42 NG AMM Wings Doc 7 02 15 Rev 4 57 TITLE Page 1 15 Mar 2018 CHAPTER 57 WINGS ...
Page 2071: ...AIRCRAFT DA 42 NG AMM Engine Doc 7 02 15 Rev 4 72 TITLE Page 1 15 Mar 2018 CHAPTER 72 ENGINE ...
Page 2288: ......
Page 2320: ......
Page 2322: ......