AIRCRAFT
DA 42 NG AMM
Oxygen System
Doc # 7.02.15
Rev. 4
35-10-00
Page 201
15 Mar 2018
Maintenance Practices
1. General
These Maintenance Practices tell you how to perform an operational test of the oxygen system. They
also tell you how to remove and install the main components of the ice protection system.
2. Operational Test
Detail Steps/Work Items
Key Items/References
(1)
Fill up the oxygen cylinder to a max. pressure of
128 bar (1850 PSI).
Do not use oxygen with a lower purity
grade than prescribed by
MIL-PRF-27210.
(2)
Check each plug-in outlet port.
Use the flow meter-needle valve
assembly; open every needle valve
completely and make sure the ball floats
to the top of the flow meter. Make sure
that every plug in is fully opened.
(3)
Check pressure gauges by comparing the one
attached on the filling block with the pressure
gauge installed in the instrument panel.
If the difference between both pressure
indications is more than 100 PSI
exchange inaccurate pressure gauge.
Use a calibrated gauge, connected on
the filling valve to determine the
inaccurate gauge.
Summary of Contents for DA 42 NG
Page 933: ...AIRCRAFT DA 42 NG AMM Fuel Doc 7 02 15 Rev 4 28 TITLE Page 1 15 Mar 2018 CHAPTER 28 FUEL ...
Page 1459: ...AIRCRAFT DA 42 NG AMM Lights Doc 7 02 15 Rev 4 33 TITLE Page 1 15 Mar 2018 CHAPTER 33 LIGHTS ...
Page 1711: ...AIRCRAFT DA 42 NG AMM Doors Doc 7 02 15 Rev 4 52 TITLE Page 1 15 Mar 2018 CHAPTER 52 DOORS ...
Page 1853: ...AIRCRAFT DA 42 NG AMM Wings Doc 7 02 15 Rev 4 57 TITLE Page 1 15 Mar 2018 CHAPTER 57 WINGS ...
Page 2071: ...AIRCRAFT DA 42 NG AMM Engine Doc 7 02 15 Rev 4 72 TITLE Page 1 15 Mar 2018 CHAPTER 72 ENGINE ...
Page 2288: ......
Page 2320: ......
Page 2322: ......