Trouble-Shooting
1. General
CAUTION:
DO NOT JACK THE AIRPLANE AND SWITCH ON THE STALL HEATER
(PITOT HEAT SWITCH)! THE HEATERS CAN BURN OUT IN A FEW
SECONDS.
The table below lists the defects you could have with the stall warning system. If you have the trouble
detailed in the Trouble column read across to the Possible Cause column. Then do the repair given
in the Repair column.
Trouble
Possible Cause
Repair
Stall warning horn does not
operate.
Circuit-breaker not set.
Stall warning horn defective.
Stall warning switch (lift
detector) defective.
Faulty cables/connectors.
Set the circuit-breaker.
Replace the stall warning horn.
Replace the stall warning
switch.
Do a test for continuity on each
cable. Do a test for short circuit
to ground and between cables.
Replace defective cables.