AIRCRAFT
Heating and Ventilation
DA 42 NG AMM
Trouble
Possible Cause
Repair
Page 102
15 Mar 2018
21-50-00
Doc # 7.02.15
Rev. 4
Insufficient cooling.
Air inlet filter contaminated.
Electrical power source
insufficient.
Hot air outlet on LH fuselage
blocked.
Leak in refrigerant circuit.
Condenser faulty.
Expansion valve faulty.
Compressor faulty.
Clean or replace filter.
Check ground power source
respective RACC power supply
of airplane.
Remove blockage.
Perform a leak test.
Repair leak.
Charge the system.
Check condenser coils for dirt
accumulation and remove dirt.
Replace expansion valve.
Replace compressor.