6. Operational Test of the Variable Elevator Stop
Detail Steps/Work Items
Key Items/References
(1)
Switch on the ELECT. MASTER.
Refer to Section 24-00.
(2)
Position both power levers above approx. 20 %
power level.
To activate the stick limiter.
(3)
Test the system:
S
Pull the control stick rearward to the stop.
Hold the stick fully rearward.
S
Set both power levers to IDLE.
S
Set both power levers above approx. 20 %.
The stick must move rearward.
The stick must move forward.
(4)
Switch off the ELECT. MASTER.
Refer to Section 24-00.