AIRCRAFT
DA 42 NG AMM
Heating and Ventilation
Detail Steps/Work Items
Key Items/References
Doc # 7.02.15
Rev. 4
21-20-00
Page 211
15 Mar 2018
(8)
Install the new inner control cable:
S
Move the new cable into position in the
outer sheath.
S
Connect the control cable to the related
heater valve flap lever:
S
Make sure that the heater valve is in the
fully closed/bypass position.
S
Move the swivel fitting into position in the
flap lever.
S
Pass the cable through the swivel fitting.
S
Tighten the swivel fitting screw.
S
Connect the control cable to the relay lever
under the pilot’s/co-pilot’s seat:
S
Move the control lever to a position 3 mm
(0.1 in) clear of the OFF position.
S
Move the swivel fitting into position in the
relay lever.
S
Pass the control cable through the swivel
fitting.
S
Tighten the swivel fitting screw.
From the cockpit control lever.
(9)
Do a test for the correct operation of the related
heater valve. If necessary, adjust the heater
valve cable.
Refer to Paragraph 4.
Summary of Contents for DA 42 NG
Page 933: ...AIRCRAFT DA 42 NG AMM Fuel Doc 7 02 15 Rev 4 28 TITLE Page 1 15 Mar 2018 CHAPTER 28 FUEL ...
Page 1459: ...AIRCRAFT DA 42 NG AMM Lights Doc 7 02 15 Rev 4 33 TITLE Page 1 15 Mar 2018 CHAPTER 33 LIGHTS ...
Page 1711: ...AIRCRAFT DA 42 NG AMM Doors Doc 7 02 15 Rev 4 52 TITLE Page 1 15 Mar 2018 CHAPTER 52 DOORS ...
Page 1853: ...AIRCRAFT DA 42 NG AMM Wings Doc 7 02 15 Rev 4 57 TITLE Page 1 15 Mar 2018 CHAPTER 57 WINGS ...
Page 2071: ...AIRCRAFT DA 42 NG AMM Engine Doc 7 02 15 Rev 4 72 TITLE Page 1 15 Mar 2018 CHAPTER 72 ENGINE ...
Page 2288: ......
Page 2320: ......
Page 2322: ......