220
LCD Message
Description
Corrective Action
UPS E10
Dependent Mode
The TeraStation is running on the UPS
battery due to a power outage. The
system will now be shut down safely.
Check that power is being supplied to the
UPS, and if there are no problems, turn on
the TeraStation.
SYSTEM Error E11
Fan Failure
An error occurred in the fan speed.
Check that no foreign objects or dust are
clogging the fan. If any foreign objects or
dust are found, use a pair of tweezers, air
duster, or other tool to remove them. If the
error is displayed again, contact Buffalo
technical support for assistance.
SYSTEM Error E12
Cooling Failure
A rise in the system temperature may
have exceeded the allowable safety value.
Do not place objects in the area around the
TeraStation. Also, move the TeraStation to a
cool location.
RAID Arrayx E14
Can't Mount
RAID array x cannot be mounted.
Run the RAID array disk check in Settings.
HDx Error E16
HDx Not Found
Unable to find hard drive x.
Hard drive x may be disconnected or may
have failed. After shutting down, reinstall
the hard drive.
HDx Error E22
HDx Can't Mount
Unable to mount drive x.
Format the hard drive. After formatting,
if the error still appears after rebooting,
replace the hard drive. If the error is
displayed again, contact Buffalo technical
support for assistance.
FailOver E27
LostBackupTarget
Unable to find the backup TeraStation.
In the main TeraStation's settings, navigate
to
Backup
-
Failover
to reconfigure the
backup TeraStation for failover.
HDx Broken E30
Replace the DISK
An error occurred, so hard drive x was
removed from the RAID array.
Replace hard drive x.
Status
After you change settings or format a hard drive, the current status is displayed on the LCD.
LCD Message
Description
Corrective Action
SYSTEM I10
TOO HOT !
System temperature is too high.
Move the TeraStation to a cool location. Do
not place objects in the area around the
TeraStation.
HDx Warning I11
Bad Sectors
Drive x has too many bad sectors.
Replace hard drive x.
Operation I12
DEGRADE MODE
Operating in degraded mode.
-
RAID I13
ARRAYxFormatting
Formatting RAID array x.
-
RAID I14
ARRAYx Checking
Checking RAID array x.
-
RAID I15
ARRAYx Scanning
Examining the error status of RAID array
x.
Note:
Transfer speeds are slower during
the examination process.
-
RAID I16
ARRAYx Creating
Creating RAID array x.
-
RAID I17
ARRAYx Resyncing
Resynchronizing RAID array x.
Note:
Transfer speeds are slower during
resynchronization.
-
Summary of Contents for TeraStation WSS 5000
Page 10: ...9 Chapter 1 Installation Diagrams TS5800D TS5800DN TS5800DWR µ µ µ µ TS5600D TS5600DN µ µ µ µ ...
Page 60: ...59 6 Click Edit under NAS Volume 7 Click Create Volume ...
Page 88: ...87 2 Click to the right of Backup 3 Click List of LinkStations and TeraStations ...
Page 90: ...89 3 Click Create New Job Note Up to 8 backup jobs can be configured ...
Page 104: ...103 18Click Time Machine ...
Page 105: ...104 19Click Select Backup Disk 20Select the TeraStation then click Use Disk ...
Page 116: ...115 3 Click Create New Job ...
Page 131: ...130 9 Click Open Squeezebox The Squeezebox s settings will open ...
Page 136: ...135 4 Open the License tab then click Activate Free License To deactivate the license click ...
Page 138: ...137 3 Click Next 4 Click Find Cameras ...
Page 144: ...143 2 Select the search criteria on the left side of the search screen then click Search ...
Page 145: ...144 3 The search results are displayed Click a thumbnail to start the media viewer ...