Application macros
89
Alternate macro
This macro provides an I/O configuration adapted to a sequence of DI control
signals used when alternating the rotation direction of the drive. To enable the
macro, set the value of parameter
to 3 (ALTERNATE).
For the parameter default values, see section
Default values with different macros
. If you use other than the default connections presented below, see
on page
.
Default I/O connections
max. 500 ohm
1…10 kohm
3)
X1A
1
SCR
Signal cable shield (screen)
2
AI1
Motor speed reference
: 0…10 V
3
GND
Analog input circuit common
4
+10V
Reference voltage: +10 VDC, max. 10 mA
5
AI2
Not in use by default. 0…10 V
6
GND
Analog input circuit common
7
AO
Motor speed value
: 0…20 mA
8
GND
Analog output circuit common
9
+24V
Auxiliary voltage output: +24 VDC, max. 200 mA
10
GND
Auxiliary voltage output common
11
DCOM
Digital input common
12
DI1
Start
forward
: If DI1 = DI2, the drive stops.
13
DI2
Start
reverse
14
DI3
Constant speed selection
1)
15
DI4
Constant speed selection
1)
16
DI5
Acceleration and deceleration selection
2)
X1B
17
ROCOM
Relay output
No fault [Fault (-1)]
18
RONC
19
RONO
20
DOSRC
Digital output, max. 100 mA
No fault [Fault (-1)]
21
DOOUT
22
DOGND
1)
See parameter group
:
2)
0 = ramp times according to parameters
and
1 = ramp times according to parameters
and
3)
360 degree grounding under a clamp.
Tightening torque = 0.5 N·m / 4.4 lbf. in.
DI3 DI4 Operation (parameter)
0
0 Set speed through AI1
1
0 Speed 1 (
)
0
1 Speed 2 (
)
1
1 Speed 3 (
)
Summary of Contents for ACS350 Series
Page 1: ...ACS350 User s Manual ACS350 Drives 0 37 22 kW 0 5 30 HP ...
Page 4: ......
Page 8: ...Safety 8 ...
Page 18: ...Table of contents 18 ...
Page 24: ...Hardware description 24 ...
Page 44: ...Installation checklist 44 ...
Page 56: ...Start up control with I O and ID Run 56 ...
Page 140: ...Program features 140 ...
Page 242: ...Actual signals and parameters 242 ...
Page 266: ...Fieldbus control with embedded fieldbus 266 ...
Page 284: ...Fault tracing 284 ...
Page 288: ...Maintenance and hardware diagnostics 288 ...
Page 309: ...Dimensions 309 Frame size R2 IP20 NEMA 1 3AFE68586658 A Frame size R2 IP20 NEMA 1 VAR EMC ...
Page 311: ...Dimensions 311 Frame size R3 IP20 NEMA 1 3AFE68579872 B Frame size R3 IP20 NEMA 1 VAR EMC ...
Page 313: ......