Actual signals and parameters
154
3421
OUTPUT3 MAX
Sets the maximum display value for the signal selected by
parameter 3415 SIGNAL3 PARAM.
-
35
MOTOR TEMP MEAS
Motor temperature measurement.
3501
SENSOR TYPE
Activates the motor temperature measurement function and
selects the sensor type.
NONE
3502
INPUT SELECTION
Selects the source for the motor temperature measurement
signal.
AI1
3503
ALARM LIMIT
Defines the alarm limit for motor temperature measurement.
0
3504
FAULT LIMIT
Defines the fault trip limit for motor temperature measurement.
0
3505
AO EXCITATION
Enables current feed from analog output AO.
DISABLE
36
TIMED FUNCTIONS
Time periods 1 to 4 and booster signal.
3601
TIMERS ENABLE
Selects the source for the timed function enable signal.
NOT SEL
3602
START TIME 1
Defines the daily start time 1.
0
3603
STOP TIME 1
Defines the daily stop time 1.
0
3604
START DAY 1
Defines the start day 1.
MONDAY
3605
STOP DAY 1
Defines the stop day 1.
MONDAY
3606
START TIME 2
See parameter 3602 START TIME 1.
3607
STOP TIME 2
See parameter 3603 STOP TIME 1.
3608
START DAY 2
See parameter 3604 START DAY 1.
3609
STOP DAY 2
See parameter 3605 STOP DAY 1.
3610
START TIME 3
See parameter 3602 START TIME 1.
3611
STOP TIME 3
See parameter 3603 STOP TIME 1.
3612
START DAY 3
See parameter 3604 START DAY 1.
3613
STOP DAY 3
See parameter 3605 STOP DAY 1.
3614
START TIME 4
See parameter 3602 START TIME 1.
3615
STOP TIME 4
See parameter 3603 STOP TIME 1.
3616
START DAY 4
See parameter 3604 START DAY 1.
3617
STOP DAY 4
See parameter 3605 STOP DAY 1.
3622
BOOSTER SEL
Selects the source for the booster activation signal.
NOT SEL
3623
BOOSTER TIME
Defines the time inside which the booster is deactivated after the
booster activation signal is switched off.
0
3626
TIMED FUNC 1 SRC
Selects the time periods for TIMED FUNC 1 SCR.
NOT SEL
3627
TIMED FUNC 2 SRC
See parameter 3626 TIMED FUNC 1 SRC.
3628
TIMED FUNC 3 SRC
See parameter 3626 TIMED FUNC 1 SRC.
3629
TIMED FUNC 4 SRC
See parameter 3626 TIMED FUNC 1 SRC.
40
PROCESS PID SET 1
Process PID (PID1) control parameter set 1.
4001
GAIN
Defines the gain for the process PID controller.
1
4002
INTEGRATION TIME
Defines the integration time for the process PID1 controller.
60
4003
DERIVATION TIME
Defines the derivation time for the process PID controller.
0
4004
PID DERIV FILTER
Defines the filter time constant for the derivative part of the
process PID controller.
1
4005
ERROR VALUE INV
Selects the relationship between the feedback signal and drive
speed.
NO
4006
UNITS
Selects the unit for PID controller actual values.
%
4007
UNIT SCALE
Defines the decimal point location for the display parameter
selected by parameter 4006 UNITS.
1
4008
0% VALUE
Defines together with parameter 4009 100% VALUE the scaling
applied to the PID controller’s actual values.
0
4009
100% VALUE
Defines together with parameter 4008 0% VALUE the scaling
applied to the PID controller’s actual values.
100
4010
SET POINT SEL
Selects the source for the process PID controller reference
signal.
AI1
Parameters – short form list
Index
Name/Selection
Description
Def
Custom
Summary of Contents for ACS350 Series
Page 1: ...ACS350 User s Manual ACS350 Drives 0 37 22 kW 0 5 30 HP ...
Page 4: ......
Page 8: ...Safety 8 ...
Page 18: ...Table of contents 18 ...
Page 24: ...Hardware description 24 ...
Page 44: ...Installation checklist 44 ...
Page 56: ...Start up control with I O and ID Run 56 ...
Page 140: ...Program features 140 ...
Page 242: ...Actual signals and parameters 242 ...
Page 266: ...Fieldbus control with embedded fieldbus 266 ...
Page 284: ...Fault tracing 284 ...
Page 288: ...Maintenance and hardware diagnostics 288 ...
Page 309: ...Dimensions 309 Frame size R2 IP20 NEMA 1 3AFE68586658 A Frame size R2 IP20 NEMA 1 VAR EMC ...
Page 311: ...Dimensions 311 Frame size R3 IP20 NEMA 1 3AFE68579872 B Frame size R3 IP20 NEMA 1 VAR EMC ...
Page 313: ......