Control panels
67
Assistant Control Panel
Features
The Assistant Control Panel features:
• alphanumeric control panel with an LCD display
• language selection for the display
• Start-up Assistant to ease drive commissioning
• copy function – parameters can be copied to the control panel memory for later
transfer to other drives or for backup of a particular system.
• context sensitive help
• real time clock.
Overview
The following table summarizes the key functions and displays on the Assistant
Control Panel.
LOC
DIR
12:45
MENU
400RPM
1200 RPM
12.4 A
405 dm3/s
3
4
5
6
7
8
9
10
No. Use
1
Status LED – Green for normal operation. If LED is flashing, or red, see
section
on page
2
LCD display – Divided into three main areas:
a. Status line – variable, depending on the mode of operation, see section
b. Center – variable; in general, shows signal and parameter values, menus or
lists. Shows also faults and alarms.
c. Bottom line – shows current functions of the two soft keys and, if enabled,
the clock display.
3
Soft key 1 – Function depends on the context. The text in the lower left corner
of the LCD display indicates the function.
4
Soft key 2 – Function depends on the context. The text in the lower right
corner of the LCD display indicates the function.
5
Up –
• Scrolls up through a menu or list displayed in the center of the LCD display.
• Increments a value if a parameter is selected.
• Increments the reference value if the upper right corner is highlighted.
Holding the key down changes the value faster.
6
Down –
• Scrolls down through a menu or list displayed in the center of the LCD
display.
• Decrements a value if a parameter is selected.
• Decrements the reference value if the upper right corner is highlighted.
Holding the key down changes the value faster.
7
LOC/REM – Changes between local and remote control of the drive.
8
Help – Displays context sensitive information when the key is pressed. The
information displayed describes the item currently highlighted in the center of
the display.
9
STOP – Stops the drive in local control.
10 START – Starts the drive in local control.
5 A
1 Hz
7 %
10
.
0
.
49
.
49.1Hz
LOC
DIR
MENU
00:00
1
2a
2b
2c
Summary of Contents for ACS350 Series
Page 1: ...ACS350 User s Manual ACS350 Drives 0 37 22 kW 0 5 30 HP ...
Page 4: ......
Page 8: ...Safety 8 ...
Page 18: ...Table of contents 18 ...
Page 24: ...Hardware description 24 ...
Page 44: ...Installation checklist 44 ...
Page 56: ...Start up control with I O and ID Run 56 ...
Page 140: ...Program features 140 ...
Page 242: ...Actual signals and parameters 242 ...
Page 266: ...Fieldbus control with embedded fieldbus 266 ...
Page 284: ...Fault tracing 284 ...
Page 288: ...Maintenance and hardware diagnostics 288 ...
Page 309: ...Dimensions 309 Frame size R2 IP20 NEMA 1 3AFE68586658 A Frame size R2 IP20 NEMA 1 VAR EMC ...
Page 311: ...Dimensions 311 Frame size R3 IP20 NEMA 1 3AFE68579872 B Frame size R3 IP20 NEMA 1 VAR EMC ...
Page 313: ......