background image

 

 

FIRST STEPS

INSTALLATION GUIDE

Ultrasonic Sensors Series UFP

For further information please see the data sheet at www.waycon.biz/products/ultrasonic-sensors/

MOUNTING THE SENSOR

WayCon Positionsmesstechnik GmbH would like to thank you for the trust you have placed in us and our 
products. This manual will make you familiar with the installation and operation of our ultrasonic sensors. 
Please read this manual carefully before initial operation!
Unpacking and checking:
Carefully lift the device out of the box by grabbing the housing. After unpacking the device, check it for 
any  visible  damage  as  a  result  of  rough  handling  during  the  shipment.  Check  the  delivery  for 
completeness. If necessary consult the transportation company, or contact WayCon directly.

ELECTRICAL CONNECTION

Ultrasonic  sensors  may  be  installed  in  any  position,  as  long  as  depositions  like  dust,  spray  mist,  or 
condensing humidity are avoided on the sound active membrane. 
It is important to avoid structure-borne sound bridges between the sensor and it's holder. 
In case several ultrasonic sensors are used in one application, it is important to leave sufficient distance  
between them. Otherwise the sensors may interact which leads to false measurement values.
By  using  a  sound  deflection  angle  the  sound  beam  can  be  redirected,  at  the  expense  of  the  sensor's 
maximum measurement range. A plain and hard surface should be used for the defection of the sound 
beam. Redirecting the sound beam with multiple sound deflection angles should be avoided.

UFP-200

Pin 1

+24 V

Pin 2

Teach-In

Pin 3

0 V

Pin 4

Switch, Analog Output

 

Pin 1

+24 V

Pin 3

0 V

Pin 4
Pin 5

Teach-In

UFP-400 to 3500, Analog Output

Analog Output

 

UFP-400 to 3500, Switching Output

Pin 1

+24 V

Pin 2

Switching Point P2

Pin 3

0 V

Pin 4

Switching Point P1

Pin 5

Teach-In

 

Summary of Contents for UFP Series

Page 1: ...rs may be installed in any position as long as depositions like dust spray mist or condensing humidity are avoided on the sound active membrane It is important to avoid structure borne sound bridges b...

Page 2: ...at www waycon biz products ultrasonic sensors UFP 200 range 250 mm output 1 x switching point or 0 10 V UFP 400 500 800 1600 2000 range up to 2000 mm output 2 x switching points or 0 10 V or 4 20 mA...

Page 3: ...of the sound cone depends on the air pressure temperature humidity and the size of the target UFP 200 UFP 400 UFP 500 UFP 800 UFP 1600 UFP 2000 UFP 3500 Guaranteed detection of a target 100 x 100 mm2...

Page 4: ...w characteristic curves The two positions P1 and P2 must be taught Sensor with switching output The teaching procedure is used to set the operation mode of the switching output and the 2 switching poi...

Page 5: ...til P1 and Echo LEDs start blinking with a 2 Hz frequency UFP 200 just yellow and then release the contact The sensor is now in the Teach In mode for P1 P1 LED will now blink with 1 Hz frequency UFP 2...

Page 6: ...and P2 For each set point and during the teaching procedure when the LED is ON when contacting and releasing the teach in line to ground the switching output will have NO characteristics when doing th...

Page 7: ...surrounding air For this reason the sound beam may be strongly diverted vertically to it s axis so that the echo is weakened or can no longer be received at all For convex cylindrical and spherical s...

Page 8: ...ACCESSORIES PIN Cable colour 1 brown 2 white 3 blue 4 black 5 grey UFP 400 3500 Cable with M12 connector 5 pole shielded K5P2M S M12 K5P5M S M12 K5P10M S M12 K5P2M SW M12 K5P5M SW M12 K5P10M SW M12 2...

Reviews: