Actual signals and parameters
177
DI5(INV)
See selection DI1(INV).
-5
NOT SEL
No start signal
0
DI1
Timer start through digital input DI1. Timer start by rising edge of digital input
DI1.
Note:
Timer start is not possible when reset is active (parameter
TIMER RESET).
1
DI2
See selection DI1.
2
DI3
See selection DI1.
3
DI4
See selection DI1.
4
DI5
See selection DI1.
5
START
External start signal, e.g. start signal through fieldbus
6
1903
TIMER RESET
Selects the source for the timer reset signal.
NOT SEL
DI1(INV)
Timer reset through inverted digital input DI1. 0 = active, 1 = inactive.
-1
DI2(INV)
See selection DI1(INV).
-2
DI3(INV)
See selection DI1(INV).
-3
DI4(INV)
See selection DI1(INV).
-4
DI5(INV)
See selection DI1(INV).
-5
NOT SEL
No reset signal
0
DI1
Timer reset through digital input DI1. 1 = active, 0 = inactive.
1
DI2
See selection DI1.
2
DI3
See selection DI1.
3
DI4
See selection DI1.
4
DI5
See selection DI1.
5
START
Timer reset at start. Start signal source is selected by parameter
TIMER
START.
6
START (INV)
Time reset at start (inverted), i.e. timer is reset when start signal is
deactivated. Start signal source is selected by parameter
TIMER
START.
7
RESET
External reset, e.g. reset through fieldbus
8
1904
COUNTER ENABLE
Selects the source for the counter enable signal.
DISABLED
DI1(INV)
Counter enable signal through inverted digital input DI1. 0 = active,
1 = inactive.
-1
DI2(INV)
See selection DI1(INV).
-2
DI3(INV)
See selection DI1(INV).
-3
DI4(INV)
See selection DI1(INV).
-4
DI5(INV)
See selection DI1(INV).
-5
DISABLED
No counter enable
0
DI1
Counter enable signal through digital input DI1. 1 = active, 0 = inactive.
1
DI2
See selection DI1.
2
DI3
See selection DI1.
3
DI4
See selection DI1.
4
DI5
See selection DI1.
5
Parameters – complete descriptions
Index Name/Selection
Description
Def, FbEq
Summary of Contents for ACS350 Series
Page 1: ...ACS350 User s Manual ACS350 Drives 0 37 22 kW 0 5 30 HP ...
Page 4: ......
Page 8: ...Safety 8 ...
Page 18: ...Table of contents 18 ...
Page 24: ...Hardware description 24 ...
Page 44: ...Installation checklist 44 ...
Page 56: ...Start up control with I O and ID Run 56 ...
Page 140: ...Program features 140 ...
Page 242: ...Actual signals and parameters 242 ...
Page 266: ...Fieldbus control with embedded fieldbus 266 ...
Page 284: ...Fault tracing 284 ...
Page 288: ...Maintenance and hardware diagnostics 288 ...
Page 309: ...Dimensions 309 Frame size R2 IP20 NEMA 1 3AFE68586658 A Frame size R2 IP20 NEMA 1 VAR EMC ...
Page 311: ...Dimensions 311 Frame size R3 IP20 NEMA 1 3AFE68579872 B Frame size R3 IP20 NEMA 1 VAR EMC ...
Page 313: ......