Control panels
69
Initially, the panel is in the Output mode, where you can
start, stop, change the direction, switch between local and
remote control, modify the reference value and monitor up
to three actual values. To do other tasks, go first to the
Main menu and select the appropriate mode on the menu.
The status line (see section
) shows
the name of the current menu, mode, item or state.
How to do common tasks
The table below lists common tasks, the mode in which you can perform them and
the page number where the steps to do the task are described in detail.
Task
Mode
Page
How to get help
Any
How to find out the panel version
At power up
How to adjust the display contrast
Output
How to switch between local and remote control
Any
How to start and stop the drive
Any
How to change the direction of the motor rotation
Output
How to set the speed, frequency or torque reference
Output
How to change the value of a parameter
Parameters
How to select the monitored signals
Parameters
How to do guided tasks (specification of related parameter sets)
with assistants
Assistants
How to view and edit changed parameters
Changed Parameters
How to view faults
Fault Logger
How to reset faults and alarms
Output, Fault
How to show/hide the clock, change date and time formats, set the
clock and enable/disable automatic clock transitions according to
the daylight saving changes
Time and Date
How to copy parameters from the drive to the control panel
Parameter Backup
How to restore parameters from the control panel to the drive
Parameter Backup
How to view backup information
Parameter Backup
How to edit and change parameter settings related to I/O terminals I/O Settings
PARAMETERS
ASSISTANTS
CHANGED PAR
EXIT
ENTER
00:00
MAIN MENU
1
LOC
5 A
1 Hz
7 %
10.
0.
49.
49.1Hz
LOC
DIR
MENU
00:00
Summary of Contents for ACS350 Series
Page 1: ...ACS350 User s Manual ACS350 Drives 0 37 22 kW 0 5 30 HP ...
Page 4: ......
Page 8: ...Safety 8 ...
Page 18: ...Table of contents 18 ...
Page 24: ...Hardware description 24 ...
Page 44: ...Installation checklist 44 ...
Page 56: ...Start up control with I O and ID Run 56 ...
Page 140: ...Program features 140 ...
Page 242: ...Actual signals and parameters 242 ...
Page 266: ...Fieldbus control with embedded fieldbus 266 ...
Page 284: ...Fault tracing 284 ...
Page 288: ...Maintenance and hardware diagnostics 288 ...
Page 309: ...Dimensions 309 Frame size R2 IP20 NEMA 1 3AFE68586658 A Frame size R2 IP20 NEMA 1 VAR EMC ...
Page 311: ...Dimensions 311 Frame size R3 IP20 NEMA 1 3AFE68579872 B Frame size R3 IP20 NEMA 1 VAR EMC ...
Page 313: ......