Technical data
297
Control connections
Analog inputs X1A: 2 and 5
Voltage signal, unipolar
0 (2)…10 V,
R
in
> 312 kohm
bipolar
-10…10 V,
R
in
> 312 kohm
Current signal, unipolar
0 (4)…20 mA,
R
in
= 100 ohm
bipolar
-20…20 mA,
R
in
= 100 ohm
Potentiometer reference value (X1A: 4) 10 V ± 1%, max. 10 mA,
R
< 10 kohm
Resolution
0.1%
Accuracy
±1%
Analog output X1A: 7
0 (4)…20 mA, load < 500 ohm
Auxiliary voltage X1A: 9
24 VDC ± 10%, max. 200 mA
Digital inputs X1A: 12…16
(frequency input X1A: 16)
Voltage
12…24 VDC with internal or external supply
Type
PNP and NPN
Frequency input
Pulse train 0…16 kHz (X1A: 16 only)
Input impedance
2.4 kohm
Relay output X1B: 17…19
Type
NO + NC
Max. switching voltage
250 VAC / 30 VDC
Max. switching current
0.5 A / 30 VDC; 5 A / 230 VAC
Max. continuous current
2 A rms
Digital output X1B: 20…21
Type
Transistor output PNP
Max. switching voltage
30 VDC
Max. switching current
100 mA / 30 VDC, short-circuit protected
Frequency
10 Hz …16 kHz
Resolution
1 Hz
Accuracy
0.2%
Wire size
1.5...0.25 mm
2
16...24 AWG
Torque
0.5 N·m / 4.4 lbf in.
Brake resistor connection
Short-circuit protection
(IEC 61800-5-1, IEC 60439-1,
UL 508C)
The brake resistor output is conditionally short-circuit proof by IEC/EN 61800-5-1 and
UL 508C. For correct fuse selection, contact your local ABB representative. Rated
conditional short-circuit current as defined in IEC 60439-1 and the Short-circuit test current
by UL 508C is 100 kA.
Efficiency
Approximately 95 to 98% at nominal power level, depending on the drive size and options
Cooling
Method
R0: Natural convection cooling. R1…R4: Internal fan, flow direction from bottom to top.
Free space around the drive
, page
.
Degrees of protection
IP20 (cabinet installation) / UL open: Standard enclosure. The drive must be installed in a
cabinet to fulfil the requirements for shielding from contact.
IP20 / NEMA 1: Achieved with an option kit including a hood and a connection box.
Summary of Contents for ACS350 Series
Page 1: ...ACS350 User s Manual ACS350 Drives 0 37 22 kW 0 5 30 HP ...
Page 4: ......
Page 8: ...Safety 8 ...
Page 18: ...Table of contents 18 ...
Page 24: ...Hardware description 24 ...
Page 44: ...Installation checklist 44 ...
Page 56: ...Start up control with I O and ID Run 56 ...
Page 140: ...Program features 140 ...
Page 242: ...Actual signals and parameters 242 ...
Page 266: ...Fieldbus control with embedded fieldbus 266 ...
Page 284: ...Fault tracing 284 ...
Page 288: ...Maintenance and hardware diagnostics 288 ...
Page 309: ...Dimensions 309 Frame size R2 IP20 NEMA 1 3AFE68586658 A Frame size R2 IP20 NEMA 1 VAR EMC ...
Page 311: ...Dimensions 311 Frame size R3 IP20 NEMA 1 3AFE68579872 B Frame size R3 IP20 NEMA 1 VAR EMC ...
Page 313: ......