Mechanical installation
26
Delivery check
Check that there are no signs of damage. Notify the shipper immediately if damaged
components are found.
Before attempting installation and operation, check the information on the type
designation label of the drive to verify that the drive is of the correct type. The type
designation label is attached to the left side of the drive. An example label and
explanation of the label contents are shown below.
Before installation
The ACS350 may be installed on the wall or in a cabinet. Check the enclosure
requirements for the need to use the NEMA 1 option in wall installations (see chapter
The drive can be mounted in three different ways, depending on the frame size:
a) back mounting (all frame sizes)
b) side mounting (frame sizes R0…R2)
c) DIN rail mounting (all frame sizes).
The drive must be installed in an upright position. Check the installation site
according to the requirements below. Refer to chapter
for frame details.
Requirements for the installation site
See chapter
for the allowed operation conditions of the drive.
Wall
The wall should be as close to vertical and even as possible, of non-flammable
material and strong enough to carry the weight of the drive.
Floor
The floor/material below the installation should be non-flammable.
Free space around the drive
The required free space for cooling above and below the drive is 75 mm (3 in.). No
free space is required on the sides of the drive, so they can be mounted side by side.
ACS350-03E-08A8-4
IP20 / UL Open type
lll
llllllllll
llllllllll
lllllllll
lll
llll
4 kW (5 HP)
S/N YWWRXXXX
U1 3~380…480
V
lllll
llllllllllll
lll
llllll
llll
llllllllll
I1
13.6 A
68468167
f1 48…63
Hz
U2
3~0…U1 V
I2
8.8 A (150% 1/10 min)
RoHS
f2
0…500 Hz
Type designation label
1 Type code, see section
on page
2 Degree of protection (IP and UL/NEMA)
3 Nominal ratings, see section
.
4 Serial number of format YWWRXXXXWS, where
Y:
5…9, A, … for 2005…2009, 2010, …
WW: 01, 02, 03, … for week 1, week 2, week 3, …
R:
A, B, C, … for product revision number
XXXX: Integer starting every week from 0001
5 ABB MRP code of the drive
6 CE marking and C-Tick, C-UL US and RoHS marks
(the label of your drive shows the valid markings)
2
3
4
5
1
6
Summary of Contents for ACS350 Series
Page 1: ...ACS350 User s Manual ACS350 Drives 0 37 22 kW 0 5 30 HP ...
Page 4: ......
Page 8: ...Safety 8 ...
Page 18: ...Table of contents 18 ...
Page 24: ...Hardware description 24 ...
Page 44: ...Installation checklist 44 ...
Page 56: ...Start up control with I O and ID Run 56 ...
Page 140: ...Program features 140 ...
Page 242: ...Actual signals and parameters 242 ...
Page 266: ...Fieldbus control with embedded fieldbus 266 ...
Page 284: ...Fault tracing 284 ...
Page 288: ...Maintenance and hardware diagnostics 288 ...
Page 309: ...Dimensions 309 Frame size R2 IP20 NEMA 1 3AFE68586658 A Frame size R2 IP20 NEMA 1 VAR EMC ...
Page 311: ...Dimensions 311 Frame size R3 IP20 NEMA 1 3AFE68579872 B Frame size R3 IP20 NEMA 1 VAR EMC ...
Page 313: ......