Actual signals and parameters
169
FAULT(RST)
Fault. Automatic reset after the autoreset delay. See parameter group
15
FLT/ALARM
Fault or alarm
16
EXT CTRL
Drive is under external control.
17
REF 2 SEL
External reference REF 2 is in use.
18
CONST FREQ
A constant speed is in use. See parameter group
19
REF LOSS
Reference or active control location is lost.
20
OVERCURRENT
Alarm/Fault by overcurrent protection function
21
OVERVOLTAGE
Alarm/Fault by overvoltage protection function
22
DRIVE TEMP
Alarm/Fault by drive overtemperature protection function
23
UNDERVOLTAGE
Alarm/Fault by undervoltage protection function
24
AI1 LOSS
Analog input AI1 signal is lost.
25
AI2 LOSS
Analog input AI2 signal is lost.
26
MOTOR TEMP
Alarm/Fault by motor overtemperature protection function. See parameter
MOT THERM PROT.
27
STALL
Alarm/Fault by stall protection function. See parameter
STALL
FUNCTION.
28
UNDERLOAD
Alarm/Fault by underload protection function. See parameter
UNDERLOAD FUNC
29
PID SLEEP
PID sleep function. See parameter group
30
FLUX READY
Motor is magnetized and able to supply nominal torque.
33
USER MACRO 2
User Macro 2 is active.
34
COMM
Fieldbus control signal
COMM RO WORD. 0 = de-energize output,
1 = energize output.
35
COMM(-1)
Fieldbus control signal
COMM RO WORD. 0 = de-energize output,
1 = energize output
36
TIMED FUNC 1
Timed function 1 is active. See parameter group
.
37
TIMED FUNC 2
Timed function 2 is active. See parameter group
.
38
TIMED FUNC 3
Timed function 3 is active. See parameter group
.
39
TIMED FUNC 4
Timed function 4 is active. See parameter group
.
40
M.TRIG FAN
Cooling fan running time counter is triggered. See parameter group
41
M.TRIG REV
Revolutions counter is triggered. See parameter group
42
Parameters – complete descriptions
Index Name/Selection
Description
Def, FbEq
0134 value
Binary
DO
RO
0
000000
0
0
1
000001
0
1
2
000010
1
0
3
000011
1
1
0134 value
Binary
DO
RO
0
000000
1
1
1
000001
1
0
2
000010
0
1
3
000011
0
0
Summary of Contents for ACS350 Series
Page 1: ...ACS350 User s Manual ACS350 Drives 0 37 22 kW 0 5 30 HP ...
Page 4: ......
Page 8: ...Safety 8 ...
Page 18: ...Table of contents 18 ...
Page 24: ...Hardware description 24 ...
Page 44: ...Installation checklist 44 ...
Page 56: ...Start up control with I O and ID Run 56 ...
Page 140: ...Program features 140 ...
Page 242: ...Actual signals and parameters 242 ...
Page 266: ...Fieldbus control with embedded fieldbus 266 ...
Page 284: ...Fault tracing 284 ...
Page 288: ...Maintenance and hardware diagnostics 288 ...
Page 309: ...Dimensions 309 Frame size R2 IP20 NEMA 1 3AFE68586658 A Frame size R2 IP20 NEMA 1 VAR EMC ...
Page 311: ...Dimensions 311 Frame size R3 IP20 NEMA 1 3AFE68579872 B Frame size R3 IP20 NEMA 1 VAR EMC ...
Page 313: ......