Actual signals and parameters
239
LOAD FD SET
FlashDrop parameter values as defined by the FlashDrop file. Parameter
view is selected by parameter
PARAMETER VIEW.
FlashDrop is an optional device for fast copying of parameters to unpowered
drives. FlashDrop allows easy customisation of the parameter list, e.g.
selected parameters can be hidden. For more information, see
MFDT-01
FlashDrop User’s Manual
[3AFE68591074 (English)].
31
USER S1 LOAD
User 1 macro loaded into use. Before loading, check that the saved
parameter settings and the motor model are suitable for the application.
0
USER S1 SAVE
Save User 1 macro. Stores the current parameter settings and the motor
model.
-1
USER S2 LOAD
User 2 macro loaded into use. Before loading, check that the saved
parameter settings and the motor model are suitable for the application.
-2
USER S2 SAVE
Save User 2 macro. Stores the current parameter settings and the motor
model.
-3
USER S3 LOAD
User 3 macro loaded into use. Before loading, check that the saved
parameter settings and the motor model are suitable for the application.
-4
USER S3 SAVE
Save User 3 macro. Stores the current parameter settings and the motor
model.
-5
9904
MOTOR CTRL MODE Selects the motor control mode.
SCALAR:
FREQ
VECTOR:SPEED
Sensorless vector control mode.
Reference 1 = speed reference in rpm.
Reference 2 = speed reference in percent. 100% is the absolute maximum
speed, equal to the value of parameter
MINIMUM SPEED if the absolute value of the minimum speed is greater than
the maximum speed value).
1
VECTOR:TORQ
Vector control mode.
Reference 1 = speed reference in rpm.
Reference 2 = torque reference in percent. 100% equals nominal torque.
2
SCALAR:FREQ
Scalar control mode.
Reference 1 = frequency reference in Hz.
Reference 2 = frequency reference in percent. 100% is the absolute
maximum frequency, equal to the value of parameter
MAXIMUM
MINIMUM FREQUENCY if the absolute value of the
minimum speed is greater than the maximum speed value).
3
Parameters – complete descriptions
Index Name/Selection
Description
Def, FbEq
Summary of Contents for ACS350 Series
Page 1: ...ACS350 User s Manual ACS350 Drives 0 37 22 kW 0 5 30 HP ...
Page 4: ......
Page 8: ...Safety 8 ...
Page 18: ...Table of contents 18 ...
Page 24: ...Hardware description 24 ...
Page 44: ...Installation checklist 44 ...
Page 56: ...Start up control with I O and ID Run 56 ...
Page 140: ...Program features 140 ...
Page 242: ...Actual signals and parameters 242 ...
Page 266: ...Fieldbus control with embedded fieldbus 266 ...
Page 284: ...Fault tracing 284 ...
Page 288: ...Maintenance and hardware diagnostics 288 ...
Page 309: ...Dimensions 309 Frame size R2 IP20 NEMA 1 3AFE68586658 A Frame size R2 IP20 NEMA 1 VAR EMC ...
Page 311: ...Dimensions 311 Frame size R3 IP20 NEMA 1 3AFE68579872 B Frame size R3 IP20 NEMA 1 VAR EMC ...
Page 313: ......