Technical data
298
Ambient conditions
Environmental limits for the drive are given below. The drive is to be used in a heated
indoor controlled environment.
Operation
installed for stationary use
Storage
in the protective package
Transportation
in the protective package
Installation site altitude
0 to 2000 m (6600 ft) above
sea level
[above 1000 m (3300 ft), see
section
on page
]
-
-
Air temperature
-10 to +50°C (14 to 122°F).
No frost allowed. See section
on page
.
-40 to +70°C (-40 to +158°F) -40 to +70°C (-40 to +158°F)
Relative humidity
0 to 95%
Max. 95%
Max. 95%
No condensation allowed. Maximum allowed relative humidity is 60% in the presence of
corrosive gases.
Contamination levels
(IEC 60721-3-3,
IEC 60721-3-2,
IEC 60721-3-1)
No conductive dust allowed.
According to IEC 60721-3-3,
chemical gases: Class 3C2
solid particles: Class 3S2.
The ACS350 must be
installed in clean air
according to enclosure
classification. Cooling air
must be clean, free from
corrosive materials and
electrically conductive dust.
According to IEC 60721-3-1,
chemical gases: Class 1C2
solid particles: Class 1S2
According to IEC 60721-3-2,
chemical gases: Class 2C2
solid particles: Class 2S2
Sinusoidal vibration
(IEC 60721-3-3)
Tested according to
IEC 60721-3-3, mechanical
conditions: Class 3M4
2…9 Hz, 3.0 mm (0.12 in.)
9…200 Hz, 10 m/s
2
(33 ft/s
2
)
-
-
Shock
(IEC 60068-2-27, ISTA 1A)
-
According to ISTA 1A.
Max. 100 m/s
2
(330 ft/s
2
),
11 ms.
According to ISTA 1A.
Max. 100 m/s
2
(330 ft/s
2
),
11 ms.
Free fall
Not allowed
76 cm (30 in.)
76 cm (30 in.)
Materials
Drive enclosure
• PC/ABS 2 mm, PC+10%GF 2.5…3 mm and PA66+25%GF 1.5 mm, all in color
NCS 1502-Y (RAL 9002 / PMS 420 C)
• hot-dip zinc coated steel sheet 1.5 mm, thickness of coating 20 micrometers
• extruded aluminium AlSi.
Package
Corrugated cardboard.
Disposal
The drive contains raw materials that should be recycled to preserve energy and natural
resources. The package materials are environmentally compatible and recyclable. All
metal parts can be recycled. The plastic parts can either be recycled or burned under
controlled circumstances, according to local regulations. Most recyclable parts are marked
with recycling marks.
If recycling is not feasible, all parts excluding electrolytic capacitors and printed circuit
boards can be landfilled. The DC capacitors contain electrolyte, which is classified as
hazardous waste within the EU. They must be removed and handled according to local
regulations.
For further information on environmental aspects and more detailed recycling instructions,
please contact your local ABB distributor.
Summary of Contents for ACS350 Series
Page 1: ...ACS350 User s Manual ACS350 Drives 0 37 22 kW 0 5 30 HP ...
Page 4: ......
Page 8: ...Safety 8 ...
Page 18: ...Table of contents 18 ...
Page 24: ...Hardware description 24 ...
Page 44: ...Installation checklist 44 ...
Page 56: ...Start up control with I O and ID Run 56 ...
Page 140: ...Program features 140 ...
Page 242: ...Actual signals and parameters 242 ...
Page 266: ...Fieldbus control with embedded fieldbus 266 ...
Page 284: ...Fault tracing 284 ...
Page 288: ...Maintenance and hardware diagnostics 288 ...
Page 309: ...Dimensions 309 Frame size R2 IP20 NEMA 1 3AFE68586658 A Frame size R2 IP20 NEMA 1 VAR EMC ...
Page 311: ...Dimensions 311 Frame size R3 IP20 NEMA 1 3AFE68579872 B Frame size R3 IP20 NEMA 1 VAR EMC ...
Page 313: ......