background image

 

 

 

m2m Germany GmbH | Am Kappengraben 18-20 | 61273 Wehrheim | 06081 5873860 
 

Table of Contents

 

EGK-LW20L00 Operating Manual

 

Important safety  information

 

Read this manual  before  attempting  to install the device!  Failure  to observe  recommendations  included  in this manual  may be dangerous  or 

 

cause a violation  of the law. The manufacturer  will not be held responsible  for any loss or damage  resulting  from not following  the instructions 
of this operating  manual.

 

Do not dismantle  or modify  in any way.

 

The device  is not intended  to be used  as a reference  sensor,  and enginko  Srl will not be held  liable  for any damage  which  may result  from inaccurate 

 

readings.

 

Avoid mechanical  stress

 

Do not use any detergent  or alcohol  to clean the device.

 

Disposal information  for users

 

Pursuant to and in accordance  with Article  14 of the Directive  2012/19/EU  of the European  Parliament  on waste  electrical  and electronic

  

equipment (WEEE),  and pursuant  to and in accordance  with Article  20 of the Directive  2013/56/EU  of the European  Parliament  on

  

batteries and accumulators  and waste  batteries.

 

The barred  symbol  of the rubbish  bin  shown  on the equipment  indicates  that,  at the end of its useful  life, the product  must be collected  separately  

from other waste.

 

Please note that the lithium batteries  must be removed  from the equipment  before  it is given  as waste  and disposed  separately.  To remove  the batteries  refer  
to the specifications  in the user manual.  For additional  information  and how to carry  out disposal,  please  contact  the certified  disposal  service providers.

 

1. Description

 

The EGK-LW20L00  is a battery  powered  sensor  intended  for level measurement  up to 7 meters.  The device  sends collected  data over the LoRaWAN® 

 

network.

 

Summary of Contents for EGK-LW20L00

Page 1: ...users Pursuant to and in accordance with Article 14 of the Directive 2012 19 EU of the European Parliament on waste electrical and electronic equipment WEEE and pursuant to and in accordance with Art...

Page 2: ...reading and FW upgrade Remote configuration Storage temperature 30 C 80 C Working temperature 30 C 70 C Dimensions 64 5 58 5 44 7mm Protection grade IP67 Weight 95g 2 2Installation Toensure correct o...

Page 3: ...m2m Germany GmbH Am Kappengraben 18 20 61273 Wehrheim 06081 5873860 2 2 2 Pole mount Forinstallation on poles pillars or posts use the included bracket and fasteners...

Page 4: ...Todeploy the sensor download the latestLoRa ToolAndroid App to setup LoRaWAN credentials and other preferences 2 2 4 Connection Enable the Bluetooth on the smartphobne and open the App once the sensor...

Page 5: ...ON OFF The sensor is shipped completely off to prevent battery consumption during storage It is therefore necessary to carry out a first power on prior to commissioning Topower on the sensor lay the...

Page 6: ...im 06081 5873860 Successful power on is signaled by the flashing of the 3 LEDs Incase of long period of inactivity if necessary is possible to shut off again the sensor to prevent battery consumption...

Page 7: ...st be disposed of separately EGK LW20L00 is provided with a battery pack Code Description EGK 1S2PCR 4800mAh battery pack Thisis the estimated battery life in years in the worst conditions 10min readi...

Page 8: ...en 18 20 61273 Wehrheim 06081 5873860 Place the new PCB batteries pack and put them in place with the screws Place the front panel and fix it with the 4 screws After the batteries replacement internal...

Page 9: ...the operation you need a unique reset code that must be requested to enginko please provide the DevEUI of the sensor when you ask for that code Atthe end of the procedure the battery level displays 10...

Page 10: ...m2m Germany GmbH Am Kappengraben 18 20 61273 Wehrheim 06081 5873860 Upload it with LoraTool App 3 Measures Oneach reading of the sensor by LoraTool the measured distance is shown on the main page...

Page 11: ...ngs Level measurements are carried out according to few parameter settings A target over the defined range cannot be detected Read and write of parameters canbe done using LoRaTool App They have a def...

Page 12: ...m2m Germany GmbH Am Kappengraben 18 20 61273 Wehrheim 06081 5873860 3 1 1 Start mm Starting point of the measurement in mm from REFERENCE point Valuescan be set from 350 to 6650...

Page 13: ...sult at a Start distance The Start mm value is also related to other level parameters Contact enginko in case of assistance 3 1 2 Lenght mm Range of measure in mm from Start point Valuescan be set fro...

Page 14: ...m2m Germany GmbH Am Kappengraben 18 20 61273 Wehrheim 06081 5873860 Default 200 3 1 4 Power Power setting for target detection Valuescan be set from 1to 5...

Page 15: ...llowing activations on a LoRaWAN network 1 NONE sensor not activated 2 OTAA the JoinEUI and the AppKey not setted must be written to the device 3 OTAA MCF88 Over the air activation fixed keys JoinEUI...

Page 16: ...Ifnot handled in the right way can cause a unnecessary battery consumption battery life 2 years Please check chapter 2 1 4 2 Other settings Network settings please keep Any settings Change it only if...

Page 17: ...inutes Clock timed setto sincronize the reading with the internal clock Accelerometer setto enable asynchronous measure in case of shaking useful for debug 5 Passwords The device can be protected by p...

Page 18: ...with the actual configuration of the sensor will be generated This is useful to store or clone the configuration or to send it toenginko s support if needed 6 1Multi devices configuration WIth LoRa T...

Page 19: ...e Enable or disable the use of the specific configuration by file Verifythe passwords Writing the passwords Fordetails on files format please ask to enginko 7 LoRaWEB Tool enginko provides upon free r...

Page 20: ...e Ordering Code Description EGK LW20L00 LoRaWAN level sensor 10 Declaration of conformity Hereby enginko Srl declares that EGK LW20L00 complies with the essential requirements and other relevant provi...

Reviews: