4.1.6 LCD Keypad Display and Keys
Note: LCD Copy Keypad is an optional keypad for remote mounting only.
The LCD keypad (PN: JN5-OP-A02) has a built-in parameter copy function (non-volatile memory) to copy
parameters from one inverter to another one.
LCD Display
Run Status
Indicator
8 button
Membrane Keypad
Stop Status
Indicator
Fault Status
Indicator
Forward Direction
Status Indicator
Reverse Direction
Status Indicator
External Reference
Indicator
External Sequence
Indicator
Fref Ref
12-16=005.00Hz
Monitor
12-17=000.00Hz
12-18=0000.0A
FWD
REV
DISPLAY
Description
LCD Display
Monitor inverter signals, view / edit parameters, fault / alarm display.
LED INDICATORS
FAULT
LED ON when a fault or alarm is active.
FWD
LED ON when inverter is running in forward direction, flashing when stopping.
REV
On when inverter is running in reverse direction, flashing when stopping.
SEQ
LED ON when RUN command is from the external control terminals or from serial
communication
REF
LED ON when Frequency Reference command is from the external control terminals
or from serial communication