4-211
READ: Copy inverter parameters to the keypad
Steps
LCD Display (English)
Description
1
Group
14 PLC Setting
15 PLC Monitor
16 LCD Keypad Func.
Select function group (16) from the group menu.
2
PARA 16
-08
:
READ Sel
-09
:
Keypad Loss Sel
-07
:
Copy Sel
Press the Read / Enter key and select parameter (16-07)
copy sel.
3
Edit 16-07
Copy Sel
Normal
(0
–
3)
< 0 >
0
Press the Read / Enter key to change value of 16-07.
4
Edit 16-07
Copy Sel
READ
(0
–
3)
< 0 >
1
Change the set value to 1 (READ) by using the up arrow
key.
5
-ADV-
READ
INV
→
OP
(1) Use Read / Enter key to enable the read operation.
(2) The bottom of LCD display will show a status bar to
indicate the read progress.
6
-ADV-
READ
COMPLETE
“READ COMPLETE” will be displayed on the keypad when
read operation was successful.
RDP
Read Prohibited
(1) The error message of "RDP Read Prohibited" is
displayed when reading parameters from the inverter
is prohibited.
(2) If this error is displayed, press any key to continue go
back to parameter 16-07.
7
Edit 16-07
Copy Sel
READ
(0
–
3)
< 0 >
1
When DSP/FUN key is pressed, the display returns back to
parameter 16-07.