4-50
Group 17 Automatic Tuning Parameters
Code
Parameter Name
Setting Range
Default
Unit
Control Mode
Attribute
V/F
SLV
PM
SLV
17-00
Mode Selection of
Automatic Tuning*
0
:
Rotation Auto-tuning
V/F: 2
SLV: 6
-
O
O
X
1
:
Static Auto-tuning
2
:
Stator Resistance Measurement
3
:
Reserved
4
:
Loop Tuning
5
:
Rotation Auto-tuning
Combination (item: 4+2+0)
6
:
Static Auto-tuning
Combination (item: 4+2+1)
17-01 Motor Rated Output Power 0.00~600.00
KVA
KW
O
O
X
17-02 Motor Rated Current
0.1~1200.0
KVA
A
O
O
X
17-03 Motor Rated Voltage
200V
:
50.0~240.0
220
V
O
O
X
400V
:
100.0~480.0
440
17-04 Motor Rated Frequency
4.8~599.0
60.0
Hz
O
O
X
17-05 Motor Rated Speed
0~24000
KVA
rpm
O
O
X
17-06 Pole Number of Motor
2~16(Even)
4
Pole
O
O
X
17-08 Motor no-load Voltage
200V
:
50~240
-
V
O
O
X
400V
:
100~480
17-09 Motor Excitation Current 0.01~600.00
-
A
X
O
X
17-10 Automatic Tuning Start
0
:
Disable
0
-
O
O
X
1
:
Enable
17-11
Error History of Automatic
Tuning
0
:
No error
0
-
O
O
X
1
:
Motor data error
2
:
Stator resistance tuning error
3
:
Leakage induction tuning error
4
:
Rotor resistance tuning error
5
:
Mutual induction tuning error
6
:
DT Error
7
:
Encoder error
8
:
Motor’s acceleration error
9
:
Warning
17-12
Proportion of Motor
Leakage Inductance
0.1~15.0
3.4
%
X
O
X
17-13 Motor Slip Frequency
0.10~20.00
1.00
Hz
X
O