4-20
Group 03 External Digital Input and Output Parameters
Code
Parameter Name
Setting Range
Default Unit
Control mode
Attribute
V/F
SLV
PM
SLV
03-00
Multifunction Input
Terminal S1
0
:
Forward/Stop Command
0
-
O
O
O
1
:
Reverse/Stop Command
O
O
O
2
:
Multi-Speed/Position Setting Command 0
O
O
O
3
:
Multi-Speed/Position Setting Command 1
O
O
O
4
:
Multi-Speed/Position Setting Command 2
O
O
O
5
:
Multi-Speed/Position Setting Command 3
O
O
O
6
:
Forward Jog Run Command
O
O
O
03-01
Multifunction Input
Terminal S2
7
:
Reverse Jog Run Command
1
-
O
O
O
8
:
UP Frequency Increasing Command
O
O
O
9
:
DOWN Frequency Decreasing Command
O
O
O
10
:
Acceleration/ Deceleration Time Selection 2
O
O
O
11
:
Inhibit Acceleration/ Deceleration Command
O
O
O
12
:
Main/ Alternative Run Switch Function
O
O
O
13
:
Main/ Alternative Frequency Switch Function
O
O
O
03-02
Multifunction Input
Terminal S3
14
:
Emergency Stop (decelerate to zero and stop)
2
-
O
O
O
15
:
External Baseblock Command
(coast to stop)
O
O
O
16
:
PID Control Disabled
O
O
O
17
:
Fault Reset
O
O
O
18
:
Auto Run Mode Enable
-
-
-
19
:
Speed Search
O
O
X
20
:
Energy Saving (V/F only)
O
X
X
03-03
Multifunction Input
Terminal S5
21
:
Reset PID integral value to Zero
3
-
O
O
O
22
:
Counter Input
-
-
-
23
:
Counter reset
-
-
-
24
:
PLC Input
O
O
O
25
:
Pulse width modulation measurement (S3)
O
O
O
26
:
Pulse frequency measure (S3)
O
O
O
03-04
Multifunction Input
Terminal S5
27
:
Local/Remote selection
4
-
O
O
O
28
:
Remote mode selection
-
O
O
O
29
:
Jog Frequency Selection
33
:
DC Braking
-
O
O
O
03-05
Multifunction Input
Terminal S6
34
:
Speed Search 2
17
-
O
O
X
40
:
Motor 1/Motor 2 selection
-
O
O
X
47
:
Fire mode
O
O
O
48
:
KEB Acceleration
O
X
X
65
:
Short-circuit braking
-
X
X
O
03-06
Up/Down frequency
step
0.00~5.00
O
O
O