![TECO-Westinghouse E510-201-H-U Скачать руководство пользователя страница 103](http://html.mh-extra.com/html/teco-westinghouse/e510-201-h-u/e510-201-h-u_instruction-manual_1072541103.webp)
4-38
Group 10 PID Parameters
Code
Parameters
Setting Range
Default Unit
Control Mode
Attribute
V/F
SLV
PM
SLV
10-25 PID Reversal Output Selection
0
:
No Allowing Reversal Output
0
-
O
O
O
1
:
Allow Reversal Output
10-26
PID Target Acceleration/
Deceleration Time
0.0~25.5
0.0
s
O
O
O
10-27 PID Feedback Display Bias
0 ~ 9999
0
-
O
O
O
10-28 PID Feedback Display Gain
0.00~100.00
100.00
O
O
O
10-29 PID Sleep Selection
0
:
Disable
1
-
O
O
O
1
:
Enable
2
:
Set By DI
10-30 Upper Limit of PID Target
0.0 ~ 100.0
100.0
%
O
O
O
10-31 Lower Limit of PID Target
0.0 ~ 100.0
0.0
%
O
O
O
10-33 Maximum Value of PID Feedback
1 ~ 10000
999
-
O
O
O
10-34 PID Decimal Width
0 ~ 4
1
O
O
O
10-35 PID Unit
0
:
%
0
O
O
O
*7
1
:
FPM
2
:
CFM
3
:
SPI
4
:
GPH
5
:
GPM
6
:
IN
7
:
FT
8
:
/s
9
:
/m
10
:
/h
11
:
°F
12
:
inW
13
:
HP
14
:
m/s
15
:
MPM
16
:
CMM
17
:
W
18
:
KW
19
:
m
20
:
°C
21
:
RPM
22
:
Bar
23
:
Pa
10-39
* Output Frequency Setting of PID
Disconnection
00.00~599.00
30.00
Hz
O
O
O
10-40
Selection of PID Sleep
Compensation Frequency
0
:
Disable
0
-
O
O
O
1
:
Enable