4-130
03-24
Output Under Current Detection
Range
【
0
】
: Invalid
【
1
】
: Valid
03-25
Output Under Current Detection Level
Range
【
0~999.9
】
A
03-26
Output Under Current Detection Delay Time
Range
【
0.0~655.35
】
Sec
If 03-11=55 Low Current Detection
Relay ON: When output current
≦
03-25 for the time specified in 03-26.
Relay OFF: When output current
>
03-25 for the time specified in 03-26.
Example:
03-26
Fixed
100msec
03-25
03-11
Relay
ON
I (Loading current)
100%
T
Operation
Command
ON
< 03-26
Relay Not active
03-27
Pulse Frequency Selection (S3)
Range
50~32000Hz
03-28
Pulse Frequency Gain
Range
【
0.0~1000.0
】
%
03-30
Pulse Input Selection
Range
【
0
】
: General Pulse input
【
1
】
: PWM
There are two ways to use the pulse input:
1. Pulse Frequency (Frequency reference = pulse frequency divided by 03-27 x max. frequency (01-02)
2. PWM (Frequency reference = pulse duty cycle (%) x max. frequency (01-02)