4-107
Table 4.3.28 Multi-speed operation selection
Speed
Multi-function digital input (S1 to S6)
*1
Frequency selection
Jog
frequency
reference
Multi-speed
frequency
3
Multi-speed
frequency
2
Multi-speed
frequency
1
Multi-speed
frequency
0
1
0
0
0
0
0
Frequency command 0( 05-01) or main
speed frequency
*2
2
0
0
0
0
1
Frequency command 1 ( 05-02) *3
3
0
0
0
1
0
Frequency command 2 ( 05-03)
4
0
0
0
1
1
Frequency command 3 ( 05-04)
5
0
0
1
0
0
Frequency command 4 ( 05-05)
6
0
0
1
0
1
Frequency command 5 ( 05-06)
7
0
0
1
1
0
Frequency command 6 ( 05-07)
8
0
0
1
1
1
Frequency command 7 ( 05-08)
9
0
1
0
0
0
Frequency command 8 ( 05-09)
10
0
1
0
0
1
Frequency command 9 ( 05-10)
11
0
1
0
1
0
Frequency command 10( 05-11)
12
0
1
0
1
1
Frequency command 11 ( 05-12)
13
0
1
1
0
0
Frequency command 12 ( 05-13)
14
0
1
1
0
1
Frequency command 13( 05-14)
15
0
1
1
1
0
Frequency command 14 ( 05-15)
16
0
1
1
1
1
Frequency command 15 ( 05-16)
17
1
*1
─
─
─
─
Jog frequency command (00-18)
“0”:OFF, “1”:ON, “-“:Ignore
*1:
Jog frequency terminal has a higher priority than multi-speed reference 1 to 4.
*2:
When parameter 00-05=0 (frequency reference input = digital operator), multi-speed frequency 1
will be set by 05-01 frequency reference setting1). When parameter 00-05=1 (frequency
reference input=control circuit terminal), multi-speed frequency command 1 is input through
analog command terminal AI1 or AI2).
*3:
Multi-speed operation is disabled when PID is enabled.