10-16
Warning Message (LCD display only)
LCD display
Description
Cause
Possible solutions
Operator Copy
Error
Parameters cannot be
uploaded to the operator
Inverter data transmission error,
cannot upload the data to
operator
Check operator and
control connection
RDE
Operator Write
Error
Operator cannot write data to
the inverter
The control mode in the operator
does not match the inverter.
The model name in the operator
does not match the inverter.
The firmware version in the
operator does not match the
inverter.
Check the control mode,
model name and firmware
version of the inverter.
WRE
Operator
Compare Error
Data compare failed between
operator and inverter.
Data in the inverter does not
match data saved in the operator.
Check parameters.
VRYE
Does Not Allow
to Read and
Save Data
Operator cannot read or save
inverter parameters
When 16-08=0, operator
read/save function disabled.
Check parameter 16-08
setting.
RDP