4-118
03-0X =65:
Short Circuit braking
When active stops inverter by turning on Short-circuit braking. Short-circuit braking is disabled when a run or jog
command is active.
t
01-08
(Fmin)
The large of 01-08
or 07-07
OFF
ON
OFF
ON
t
t
Run Command
or
Jog Command
Short Circuit
Braking
Command
Output
Frequency
Short
Circuit
Brake
Short
Circuit
Brake
03-06
UP/DOWN Frequency Step
Range
【
0.00~5.00
】
Hz
When 03-06 = 0 Hz, Up / Down function is maintained.
When 03-06 > 0 Hz, frequency command is the run frequency plus the value set in parameter 03-06.
Example:
03-
00=8 (S1 terminal set to “UP” frequency command)
03-
01=9 (S2 terminal set to “Down” frequency command)
03-06=
△
Hz
Mode 1:
When 03-40 = 0 Hz, Up / Down function is maintained. See Fig. 4.3.20.
Mode 2:
When 03-06 > 0 Hz and multi-function input terminals are active less than 2 sec, frequency change (
△
Hz)
based on setting in parameter 03-06.
S1
S2
ON
ON
ON
Hz
T
△
Hz
Actual output
frequency
ON
ON
ON
Lower
frequency
limit
Upper frequency
limit