4-40
Group 11 Auxiliary Parameters
Code
Parameters
Setting Range
Default Unit
Control Mode
Attribute
V/F
SLV
PM
SLV
11-36
Frequency gain of OV
Prevention
0.000 ~ 1.000
O
O
X
11-37
Frequency limit of OV
Prevention
0.00 ~ 599.00
Hz
O
O
X
11-38
Deceleration start voltage
of OV prevention
230V
:
200V~400V
300
V
O
O
X
400V
:
400V~800V
600
11-39
Deceleration end voltage
of OV Prevention
230V
:
300V~400V
350
V
O
O
X
400V
:
600V~800V
700
11-40 OV Prevention Selection
0~3
0
O
X
X
11-47 KEB Deceleration Time
0.0~25.5
0.0
s
O
X
X
11-48 KEB Detection Level
230V
:
190~210
200V
V
O
X
X
400V
:
380~420
400V
11-55 STOP Key Selection
0
:
Stop Key is Disabled when the Operation
Command is not Provided by Operator.
1
-
O
O
O
1
:
Stop Key is Enabled when the Operation
Command is not Provided by Operator.
11-59
Gain of Preventing
Oscillation
0.00~2.50
*
O
X
X
11-60
Upper Limit of Preventing
Oscillation
0~100
*
%
O
X
X
11-61
Time Parameter of
Preventing Oscillation
0~100
0
O
X
X
11-62
Selection of Preventing
Oscillation
0
:
Mode 1
1
-
O
X
X
1
:
Mode 2
2
:
Mode 3
11-63 Strong Magnetic Selection
0
:
Disable
1
-
X
O
X
1
:
Enable
11-66
2/3 Phase PWM Switch
Frequency
6.00~60.00
20
-
X
O
X
11-67 RPWM Frequency Bias
0~12000
0
-
X
O
X
11-68 RPWM Switch Frequency
6.00~60.00
20.00
Hz
X
O
X
11-69
Gain of Preventing
Oscillation 2
0.00~200.00
5.00
%
O
X
X
11-70
Upper Limit of Preventing
Oscillation 2
0.01~100.00
5.00
%
O
X
X
11-71
Time of Preventing
Oscillation 2
0~30000
100
ms
O
X
X
11-72
Switch Frequency 1 of
Preventing Oscillation 2
0.01~300.00
30.00
Hz
O
X
X
11-73
Switch Frequency 2 of
Preventing Oscillation 2
0.01~300.00
50.00
Hz
O
X
X