![TECO-Westinghouse E510-201-H-U Скачать руководство пользователя страница 199](http://html.mh-extra.com/html/teco-westinghouse/e510-201-h-u/e510-201-h-u_instruction-manual_1072541199.webp)
4-134
The filter time constant (range: 0.00 to 2.00 seconds) is defined as the time that the input step signal reaches 63%
of its final value.
Note:
Increasing the filter time causes the drive operation to become more stable but less responsive to change
to the analog input.
Unfiltered
signal
Filtered
signal
Filter time constant (04-01)
63
100
%
t
Figure 4.3.37 Filter time constant
04-11
AO function setting
Range
【
0
】
: Output frequency
【
1
】
: Frequency command
【
2
】
: Output voltage
【
3
】
: DC voltage
【
4
】
: Output current
04-12
AO gain
Range
【
0.0~1000.0
】
%
04-13
AO bias
Range
【
-100.0~100.0
】
%
04-15
AO Slope
Range
【
0
】
: Positive
【
1
】
: Negative
04-16
F-Gain / Proportional Gearing function
Range
【
0
】
: Disable
【
1
】
: Enable
For the analog output and related parameters, please refer to figure 4.3.50.
AO
Related Parameters
04-11 (Analog Output Mode)
04-12 (AO Gain)
04-13 (AO Bias)
{
Figure 4.3.50 Analog outputs and related parameters
Analog output AO adjustment (04-12, 04-13 and 04-15)
Signal:
Use parameter 04-11 to select the analog output signal for AO.