4-230
22 PM Motor Parameters
22-00
PM Motor Rated Power
Range
【
0.00~600.00
】
kW
22-02
PM Motor Rated Current
Range
25%~200% inverter’s rated current
22-03
PM Motor’s Pole Number
Range
【
2~96
】
Poles
22-04
PM Motor’s Rated Rotation Speed
Range
【
6~65535
】
rpm
22-05
PM Motor’s Maximum Rotation Speed
Range
【
6~65535
】
rpm
22-06
PM Motor Rated Frequency
Range
【
4.8~599.0
】
Hz
The PM parameter group can be restored to factory default be initializing the inverter (13-08). Set the motor rating
before initializing the inverter (13-00).
22-00: PM motor rated power
Set the motor power according to the motor nameplate.
22-02: PM motor rated current
Set the motor full load according to the motor nameplate.
22-03: PM motor pole number
Set the number of motor poles according to the motor nameplate.
22-04: PM motor rated speed
Set parameter 22-04 or 22-06, the inverter will automatically calculate one or the other.
Set the motor rated speed in rpm according to the motor nameplate.
Note:
Only set parameter 22-04 or 22-06, the inverter will automatically calculate the other one.
Formula (22-04) = 120*f (22-06) / Number of Poles (22-03)
22-05: PM motor maximum rotation speed
Set the maximum motor rated speed in rpm according to the motor nameplate.