4-53
Group 20 Speed Control Parameters
Code
Parameters
Setting Range
Default
Unit
Control Mode
Attribute
V/F
SLV
PM
SLV
Constant Speed
20-34
Compensation Gain of
Derating
0~25600
0
X
O
O
*1
20-35
Compensation Time of
Derating
0~30000
100
ms
X
O
O
*1
Group 21 Torque And Position Control Parameters
Code
Parameters
Setting Range
Default
Unit
Control mode
Attribute
V/F
SLV
PM
SLV
21-05 Positive Torque Limit
0~300
*
%
X
O
O
*
21-06 Negative Torque Limit
0~300
*
%
X
O
O
*
21-07
Forward Regenerative
Torque Limit
0~300
*
%
X
O
O
*
21-08
Reversal Regenerative
Torque Limit
0~300
*
%
X
O
O
*
*
:
Refer to attachment 1.
Group 22 PM Motor Parameters
Code
Parameters
Setting Range
Default
Unit
Control Mode
Attribute
V/F
SLV
PM
SLV
22-00 PM Motor Rated Power 0.00~600.00
KVA
kW
X
X
O
22-02
PM Motor Rated
Current
25%~200% inverter rated current
KVA
A
X
X
O
22-03
PM M
otor‘s Pole
Number
2~96
8
poles
X
X
O
22-04
PM M
otor’s
Rotation Speed
6~65535
1500
rpm
X
X
O
22-05
PM
Motor’s Maximum
Rotation Speed
6~65535
1500
rpm
X
X
O
22-06
PM Motor Rated
Frequency
4.8~599.0
75.0
Hz
X
X
O
22-10 PM SLV Start Current
20% ~ 120% Motor Rated Current
50
%
X
X
O
22-11
I/F Mode Start
Frequency Switching
Point
1.0 ~ 20.0
10.0
%
X
X
O
22-14
Armature Resistance of
PM Motor
0.001 ~ 30.000
1.000
Ω
X
X
O
22-15
D-axis Inductance of
PM Motor
0.01 ~300.00
10.00
mH
X
X