4-145
06-00= 1 to 3:
After a stop the inverter will start with the incomplete step when the run command is re-applied.
06-00= 4 to 6:
After a stop the inverter will start with the first step of the cycle when the run command is re-applied.
Notes:
ACC/DEC time in Auto run mode will be according to the setting of 00-14/00-15.
When Auto sequence is set to 0.The run frequency used is the keypad frequency set by parameter 05-01 and
parameters 06-16 and 06-31 are used to set the sequence Run time and Run direction.
1 to 3
RUN
STOP
RUN
Operation
Command
RUN
STOP
RUN
t
t
Output
Frequency
Operation
Command
Output
Frequency
Start new cycle
Continue with
incompleted step cycle
Output Frequen
cy
06-00
4 to 6
06-00