Parameter list
Parameters
1-99
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Note:
Controller gain factors are always saved as physical units.
For VECTOR (r0107) the following applies:
The parameter is pre-assigned a value of 1. The parameter cannot be changed.
Description:
This parameter is used to calculate all parameters that depend on the technology of the application (p0500).
All of the parameters are calculated that can also be determined using p0430 = 5.
Values:
0:
No calculation
1:
Complete parameterization
Note:
At the end of the calculations, p0578 is automatically set to 0.
Description:
Sets the sensor to monitor the motor temperature.
Values:
0:
No sensor
1:
Temperature sensor via encoder 1
2:
Temperature sensor via encoder 2
3:
Temperature sensor via encoder 3
10:
Temperature sensor via a BICO interconnection
11:
Temperature sensor via motor module
Dependency:
Refer to: p0601, p0603
Note:
For a value = 0, for synchronous motors, the temperature monitoring function is disabled.
For a value = 10, the BICO interconnection should be executed via p0603.
Description:
Sets the sensor type for the motor temperature monitoring.
Values:
0:
No sensor available
1:
PTC thermistor
2:
KTY84
3:
KTY84 and PTC (only for temperature sensor via encoder)
Dependency:
Refer to: p0600
Note:
PTC thermistor (p0601 = 1): Trip resistance = 1650 Ohm.
The temperature sensor for the temperature evaluation is set in p0600.
For p0600 = 10 (temperature sensor via a BICO interconnection), the setting in p0601 has no significance.
p0578[0...n]
Calculate parameters that are dependent on the technology/units / Calc techn par
VECTOR
Can be changed:
C2, T
Access level:
2
Data type:
Integer16
Data set:
DDS
Function diagram:
-
P-Group:
Applications
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 1
0
p0600[0...n]
Motor temperature sensor for monitoring / Mot temp_sensor
VECTOR
Can be changed:
C2, U, T
Access level:
2
Data type:
Integer16
Data set:
MDS
Function diagram:
8016
P-Group:
Motor
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 11
1
p0601[0...n]
Motor temperature sensor type / Mot temp_sensortyp
VECTOR
Can be changed:
C2, U, T
Access level:
2
Data type:
Integer16
Data set:
MDS
Function diagram:
8016
P-Group:
Motor
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 3
2
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...