Parameter list
Parameters
1-129
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Displays the system runtime in ms since the last power ON.
Note:
The value in p0969 can only be reset to 0.
The value overflows after approx. 49 days.
Description:
The parameter is used to initiate that the parameters of an individual drive unit are reset.
Parameters p0100, p0205 (only for VECTOR) and the parameters of the basic drive commissioning (p0009) are not
reset (p0107, p0108, p0111, p0112, p0115, p0121, p0130, p0131, p0140, p0141, p0142, p0170, p0186 ... p0189).
These can only be reset using the factory setting of the complete drive unit (p0976).
Values:
0:
not active
1:
Starts a parameter reset
100:
Starts a BICO interconnection reset
Note:
A factory setting run can only be started if p0010 was first set to 30 (parameter reset).
At the end of the calculations, p0970 is automatically set to 0.
Description:
The parameter is used to initiate that the parameters are reset on terminal board 30 (TB30).
The sampling time p4099 is not reset if in so doing a conflict occurs with the basic clock cycle.
Parameter p0161 is not reset. It is only reset if the entire drive unit is reset to the factory settings (p0976).
Values:
0:
not active
1:
Starts a parameter reset
100:
Starts a BICO interconnection reset
Note:
A factory setting run can only be started if p0010 was first set to 30 (parameter reset).
At the end of the calculations, p0970 is automatically set to 0.
Description:
The parameter is used to initiate that the parameters are reset on terminal module 31 (TB31).
The sampling time p4099 is not reset if in so doing a conflict occurs with the basic clock cycle.
Parameter p0151 is not reset. It is only reset if the entire drive unit is reset to the factory settings (p0976).
p0969
System runtime relative / t_System relative
CU
Can be changed:
T
Access level:
3
Data type:
Unsigned32
Data set:
-
Function diagram:
1750,
8060
P-Group:
Displays, signals
Units group:
TIME_M3
Unit selection:
-
Min Max
Factory
setting
0 [ms]
4294967295 [ms]
0 [ms]
p0970
Reset drive parameters / Drive par reset
VECTOR
Can be changed:
C2
Access level:
2
Data type:
Unsigned16
Data set:
-
Function diagram:
-
P-Group:
Factory settings
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 100
0
p0970
TB30 reset parameters / TB30 par reset
TB30
Can be changed:
C2
Access level:
2
Data type:
Unsigned16
Data set:
-
Function diagram:
-
P-Group:
Factory settings
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 100
0
p0970
TM31 reset parameters / TM31 par reset
TM31
Can be changed:
C2
Access level:
2
Data type:
Unsigned16
Data set:
-
Function diagram:
-
P-Group:
Factory settings
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 100
0
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...