![Siemens SINAMICS G Скачать руководство пользователя страница 405](http://html.mh-extra.com/html/siemens/sinamics-g/sinamics-g_list-manual_378180405.webp)
PROFIBUS
Function diagrams
2-405
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Picture 2-28 2460 – Receive telegram, free interconnection via BICO (p0922 = 999)
- 2460 -
8
7
6
5
4
3
2
1
fp_S01_2460_en.vsd
DO: VECTOR
SINAMICS G
17.12.04
V02.02.00
PROFIBUS - Receive telegram, free interconnection via BICO (p0922 = 999)
X126
PROFIBUS
PZD receive word 1
PZD receive word 2
r2060[0]
DWORD
PZD receive word 5
PZD receive word 6
r2060[4]
DWORD
Bit 0
r2091.0
r2050[1]
Bit 15
r2091.15
Bit 0
r2090.0
r2050[0]
Bit 15
r2090.15
...
PZD receive word 3
PZD receive word 4
r2060[2]
DWORD
Bit 0
r2093.0
r2050[3]
Bit 15
r2093.15
Bit 0
r2092.0
r2050[2]
Bit 15
r2092.15
...
...
r2060[1]
DWORD
...
PZD receive word 7
r2050[5]
r2050[4]
r2060[5]
DWORD
r2050[6]
r2060[3]
DWORD
PZD receive word 8
PZD receive word 9
r2060[6]
DWORD
r2050[7]
r2060[7]
DWORD
r2050[8]
PZD receive word 10
PZD receive word 11
PZD receive word 12
PZD receive word 13
PZD receive word 14
PZD receive word 15
PZD receive word 16
r2060[8]
DWORD
r2050[9]
r2060[9]
DWORD
r2050[10]
r2060[10]
DWORD
r2050[11]
r2060[11]
DWORD
r2050[12]
r2060[12]
DWORD
r2050[13]
r2060[13]
DWORD
r2050[14]
r2060[14]
DWORD
r2050[15]
(0)
p2099[0]
Bit 0
r2095.0
Bit 15
r2095.15
(0)
p2099[1]
Reference quantities for ongoing interconnection
p200x
<3>
<3>
2 connector-binector convert
e
r
<2>
Bit 0
r2094.0
Bit 15
r2094.15
<1>
In order to maintain the PROFIdrive profile, receive word 1 must be used as control word (STW1) (due to bit 10 "control requ
ested").
<2>
Using the connector-binector converters, the bits can be extracted from two of the PZD receive words 5 to 16 and used as bin
ectors.
<3>
For words and double words, the representation 4000 hex = 100 % or 4000 0000 hex = 100 % for double words.
Reference quantities p200x are decisive for the ongoing interconnection (100 % corresponds to p200x).
p2098[1].0
p2098[1].15
p2098[0].15
p2098[0].0
<1>
PROFIBUS
receive telegram
1
0
1
1
0
1
1
0
1
1
0
1
PROFIBUS sampling time
Refer to [1020.7]
<2>
Drive object
Header
Trailer
4000.00 µs
Function diagram
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...