Parameter list
Parameters
1-45
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Note:
The parameter can only be changed for closed-loop vector control (p0107).
The parameter value is not reset when the factory setting is restored (p0010 = 30, p0970).
Description:
The parameter contains the object number via which every drive object can be addressed.
The number of an existing drive object is entered into each index.
The numbers are automatically assigned once and cannot longer be changed as long as the object has not been
deleted.
In the commissioning software, this object number cannot be entered using the Expert list, but is automatically
assigned when inserting an object.
Note:
Value = 0: No drive object is defined.
Description:
Displays the total number of available drive objects.
Note:
The numbers of the drive objects are in p0101.
Description:
The application-specific view of an existing drive object is entered into each index.
Dependency:
Refer to: r0103, r0107, p0107
Refer to: F01051
Note:
The application-specific views are defined in files on the CompactFlash Card with the following structure:
PDxxxyyy.ACX
xxx: Application-specific view, set using p0103
yyy: Type of drive object (p0107)
Example:
PD052011.ACX
--> "011" stands for the drive object, type SERVO
--> "052" is the view for this drive object set using p0103
Description:
Displays the application-specific view of the individual drive object.
p0101[0...15]
Drive object numbers / DO numbers
CU
Can be changed:
C1
Access level:
2
Data type:
Unsigned16
Data set:
-
Function diagram:
-
P-Group:
Topology
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 62
0
r0102
Number of drive objects / DO quantity
CU
Can be changed:
-
Access level:
2
Data type:
Unsigned16
Data set:
-
Function diagram:
-
P-Group:
Topology
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
p0103[0...15]
Application-specific view / Appl_spec view
CU
Can be changed:
C1
Access level:
2
Data type:
Unsigned16
Data set:
-
Function diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 999
0
r0103
Application-specific view / Appl_spec view
VECTOR
Can be changed:
-
Access level:
2
Data type:
Unsigned16
Data set:
-
Function diagram:
-
P-Group:
Control
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...