Description:
Displays the torque setpoint before entering the supplementary torque.
For closed-loop speed control, r1508 corresponds to the speed controller output; for closed-loop torque control,
r1508 corresponds to the torque setpoint of the signal source assigned in p1503.
Description:
Sets the signal source for supplementary torque/force 1.
Description:
Sets the signal source for scaling supplementary torque/force 1.
Description:
Sets the signal source for supplementary torque/force 2.
Description:
Sets the scaling for supplementary torque 2.
r1508
CO: Torque setpoint before supplementary torque / M_set bef. M_suppl
VECTOR (n/M)
Can be changed:
-
Access level:
2
Data type:
Floating Point
Data set:
-
Function diagram:
6060,
6722
P-Group:
Control
Units group:
TORQUE
Unit selection:
-
Min Max
Factory
setting
- [Nm]
- [Nm]
- [Nm]
p1511[0...n]
CI: Supplementary torque 1 / M_suppl 1
VECTOR (n/M)
Can be changed:
T
Access level:
3
Data type:
Unsigned32
Data set:
CDS
Function diagram:
5060,
6060
P-Group:
Control
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
0
p1512[0...n]
CI: Supplementary torque 1 scaling / M_suppl 1 scal
VECTOR (n/M)
Can be changed:
T
Access level:
3
Data type:
Unsigned32
Data set:
CDS
Function diagram:
5060,
6060
P-Group:
Control
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
0
p1513[0...n]
CI: Supplementary torque 2 / M_suppl 2
VECTOR (n/M)
Can be changed:
T
Access level:
3
Data type:
Unsigned32
Data set:
CDS
Function diagram:
5060,
6060
P-Group:
Control
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
0
p1514[0...n]
Supplementary torque 2 scaling / M_suppl 2 scal
VECTOR (n/M)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
-
P-Group:
Control
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
-2000.0 [%]
2000.0 [%]
100.0 [%]
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...