For VECTOR (p0107) the following applies:
Set p1254 to 0 (automatic detection of the Vdc switch-in levels).
The switch-in thresholds of the Vdc_max controller are then directly determined using p0210.
Cautiont:
If the line supply voltage is higher than the entered value, the Vdc controller may be automatically de-activated in
some cases to prevent the motor from accelerating. In this case, an appropriate alarm is output.
Note:
For VECTOR (p0107) the following applies:
If the line supply voltage is higher than the parameterized value, then the DC link voltage controller could be auto-
matically de-activated in order to prevent the drive accelerating.
Setting ranges for p0210 as a function of the rated power module voltage:
V_rated = 400 V:
- p0210 = 380 ... 480 V (AC/AC), 510 ... 650 V (DC/AC)
V_rated = 500 V:
- p0210 = 500 ... 575 V (AC/AC), 675 ... 810 V (DC/AC)
V_rated = 690 V:
- p0210 = 660 ... 690 V (AC/AC), 890 ... 1035 V (DC/AC)
The pre-charging switch-in threshold for the DC link voltage (Vdc) is calculated from p0210:
Vdc_pre = p0210 * 0.82 * 1.35 (AC/AC)
Vdc_pre = p0210 * 0.82 (DC/AC)
The undervoltage thresholds for the DC link voltage (Vdc) are calculated from p0210 as a function of the rated
power module voltage:
V_rated = 400 V:
- V_min = p0210 * 0.78 (AC/AC), p0210 * 0.66 (DC/AC)
V_rated = 500 V:
- V_min = p0210 * 0.76 (AC/AC)
V_rated = 690 V:
- V_min = p0210 * 0.74 (AC/AC), p0210 * 0.63 (DC/AC)
Description:
Sets the type of the filter at the motor side.
Values:
0:
No filter
1:
Motor reactor
2:
dv/dt filter
3:
Sinusoidal filter, Siemens
4:
Sinusoidal filter, third-party
p0230
Drive filter type, motor side / Drv filt type
VECTOR
Can be changed:
C2
Access level:
1
Data type:
Integer16
Data set:
-
Function diagram:
-
P-Group:
Drive converter
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 4
0
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...