Parameter list
Parameters
1-357
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
With p9905 = 1, the serial numbers and the hardware versions of all of the components are transferred from the
actual topology into the target topology and a new comparison is started..
For the device specialization, the components of the target topology may only differ from those of the actual topol-
ogy by the serial numbers.
Note:
p9905 is automatically set to 0 at the end of the operation.
In order to permanently accept the data, it is necessary to save in a non-volatile fashion (p0977).
Description:
Sets the type of comparison between the actual topology and target topology.
The comparison is started by setting the required value.
Values:
0:
High: Compares the complete electronic rating plate
1:
Average: Compares the component type and the Order number
2:
Low: Compares the component type
3:
Minimum: Compares the component class
99:
Topology has different comparison stages
Note:
The electronic rating plate comprises the following data:
- component type (e.g. "SMC20")
- Order No. (e.g. "6SL3055-0AA0-5BA0")
- Manufacturer (e.g. SIEMENS)
- hardware version (e.g. "A")
- Serial No. (e.g. "T-P30050495")
When comparing the topology, the following data is compared in the target and actual topologies:
p9906 = 0: Component type, Order No., Hardware version, Manufacturer, Serial No.
p9906 = 1: Component type, Order No.
p9906 = 2: Component type
p9906 = 3: Component class (e.g. sensor module or motor module)
Description:
Enters the number of the component where the setting of how the actual topology should be compared to the target
topology should be changed.
Dependency:
Refer to: p9908
p9905
Device specialization / Device specializ.
CU
Can be changed:
C1
Access level:
3
Data type:
Unsigned16
Data set:
-
Function diagram:
-
P-Group:
Topology
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 1
0
p9906
Topology comparison, comparison stage of all components / Topo_cmpr tot comp
CU
Can be changed:
C1
Access level:
3
Data type:
Integer16
Data set:
-
Function diagram:
-
P-Group:
Topology
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 99
0
p9907
Topology comparison, comparison stage of the component number / Topo_cmpr
comp_no
CU
Can be changed:
C1
Access level:
3
Data type:
Unsigned8
Data set:
-
Function diagram:
-
P-Group:
Topology
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 199
0
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...