Parameter list
Parameters
1-179
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Sets the proportional gain for the I_max voltage controller.
Dependency:
Refer to: p1340
Description:
Sets the integral action time for the I_max voltage controller.
Dependency:
Refer to: p1340
Note:
p1346 = 0: I_max voltage controller de-activated.
Description:
Sets whether the voltage is continuously increased during the magnetizing phase (p1350 = 1, On) or whether it
jumps directly to the voltage boost (p1350 = 0, Off).
Values:
0:
Off
1:
On
Note:
The settings for this parameter have the following advantages and disadvantages:
0 = off (jump directly to voltage boost)
Advantage: Flux is established quickly -> torque is quickly available
Disadvantage: The motor can move while it is being magnetized
1 = on (voltage is continually established)
Advantage: The motor is unlikely to rotate
Disadvantage: Flux establishes itself more slowly -> delay until torque is available
Description:
Sets the configuration for the closed-loop speed control.
p1345[0...n]
I_max voltage controller proportional gain / I_max_U_ctrl Kp
VECTOR
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
1690
P-Group:
V/f control
Units group:
GAIN_CURRENT_CTRL
Unit selection:
-
Min Max
Factory
setting
0.000 [V/A]
100000.000 [V/A]
0.000 [V/A]
p1346[0...n]
I_max voltage controller integral action time / I_max_U_ctrl Tn
VECTOR
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
1690
P-Group:
V/f control
Units group:
TIME
Unit selection:
-
Min Max
Factory
setting
0.000 [s]
50.000 [s]
0.030 [s]
p1350[0...n]
Soft starting / Soft starting
VECTOR
Can be changed:
U, T
Access level:
3
Data type:
Integer16
Data set:
DDS
Function diagram:
1690
P-Group:
V/f control
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 1
0
p1400[0...n]
Speed control configuration / n_ctrl config
VECTOR (n/M)
Can be changed:
U, T
Access level:
2
Data type:
Unsigned16
Data set:
DDS
Function diagram:
6490
P-Group:
Control
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0000 bin
1111 1111 1111 1111 bin
1000 0000 0010 0001 bin
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...