Function diagrams
PROFIBUS
2-402
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Picture 2-25 2442 – STW1 control word interconnection (p2038 = 0)
- 2442 -
8
7
6
5
4
3
2
1
fp_S01_2442_en.vsd
DO: VECTOR
SINAMICS G
17.12.04
V02.02.00
PROFIBUS - STW1 control word interconnection (p2038 = 0)
Refer to [1020.7]
<1> Used in telegram 1, 999.
STW1.0
STW1.1
STW1.2
STW1.3
STW1.4
STW1.5
STW1.6
STW1.8
STW1.9
STW1.11
STW1.12
STW1.13
STW1.14
STW1.15
STW1.7
STW1.10
p0848[0] = r2090
.2
p0852[0] = r2090
.3
p1140[0] = r2090
.4
p1141[0] = r2090
.5
p1142[0] = r2090
.6
p2103[0] = r2090
.7
-
-
p0854[0] = r2090.10
p1113[0] = r2090.11
-
p1035[0] = r2090.13
p1036[0] = r2090.14
-
p0840[0] = r2090
.0
p0844[0] = r2090
.1
= ON (pulses can be enabled)
0 = OFF1
(braking with ramp-function generator, then pulse
cancellation and ready-to-power-up)
1 = No OFF2
(enable is possible)
0 = OFF2 (immediate pulse cancellation and power-on inhibit)
1 = No OFF3
(enable possible)
0 = OFF3 (braking with the OFF3 ramp p1135, then pulse cancellation and power-on inhibit)
1 = Enable operation
(pulses can be enabled)
0 = Inhibit operation (cancel pulses)
1 = operating condition
(the ramp-function generator can be enabled)
0 = inhibit ramp-function generator (set the ramp-function generator output to zero)
1 = Enable the ramp-function generator
0 = stop the ramp-function generator (freeze the ramp-function generator output)
1 = Enable setpoint
0 = inhibit setpoint (set the ramp-function generator input to zero)
= Acknowledge faults
Reserved
Reserved
1 = Control via PLC
1 = Direction of rotation reversal
Reserved
1 = Motorized potentiometer, setpoint, raise
Reserved
1 = Motorized potentiometer, setpoint, lower
[2501.3]
[2501.3]
[2501.3]
[2501.3]
[2501.3]
[2546.1]
-
-
[2501.3]
[2505.3]
-
[2505.3]
[2505.3]
-
[2501.3]
[2501.3]
Signal targets for STW1 (Interface Mode SINAMICS/MICROMASTER, p2038 = 0)
[2610]
[2610]
[3060] [3070] [3080]
[3060] [3070]
[3060] [3070] [3080]
[8060]
-
-
[2501]
[3040]
-
[3020]
[3020]
-
[2610]
[2610]
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Signal
Interconnection
parameters
Meaning
[Function chart]
internal control wo
rd
[Function chart]
signal target
Inverted
<2> Bit 10 must be set in the first PZD word of the telegram received from PROFIBUS in order that the drive accepts the process
data.
<2>
<1>
Function diagram
PROFIBUS sampling time
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...