![Siemens SINAMICS G Скачать руководство пользователя страница 109](http://html.mh-extra.com/html/siemens/sinamics-g/sinamics-g_list-manual_378180109.webp)
Parameter list
Parameters
1-109
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Sets the signal source for terminal DI/DO 12 (X132.7).
Note:
DI/DO: Bidirectional digital input/output
Prerequisite: The DI/DO must be set as an output (p0728.12 = 1).
Description:
Sets the signal source for terminal DI/DO 13 (X132.8).
Note:
DI/DO: Bidirectional digital input/output
Prerequisite: The DI/DO must be set as an output (p0728.13 = 1).
Description:
Sets the signal source for terminal DI/DO 14 (X132.10).
Note:
DI/DO: Bidirectional digital input/output
Prerequisite: The DI/DO must be set as an output (p0728.14 = 1).
Description:
Sets the signal source for terminal DI/DO 15 (X132.11).
Note:
DI/DO: Bidirectional digital input/output
Prerequisite: The DI/DO must be set as an output (p0728.15 = 1).
Description:
Displays the status of digital outputs.
p0742
BI: CU, signal source for terminal DI/DO 12 / CU S_src DI/DO 12
CU
Can be changed:
U, T
Access level:
1
Data type:
Unsigned32
Data set:
-
Function diagram:
1510,
2132
P-Group:
Commands
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
0
p0743
BI: CU, signal source for terminal DI/DO 13 / CU S_src DI/DO 13
CU
Can be changed:
U, T
Access level:
1
Data type:
Unsigned32
Data set:
-
Function diagram:
2132
P-Group:
Commands
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
0
p0744
BI: CU, signal source for terminal DI/DO 14 / CU S_src DI/DO 14
CU
Can be changed:
U, T
Access level:
1
Data type:
Unsigned32
Data set:
-
Function diagram:
2133
P-Group:
Commands
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
0
p0745
BI: CU, signal source for terminal DI/DO 15 / CU S_src DI/DO 15
CU
Can be changed:
U, T
Access level:
1
Data type:
Unsigned32
Data set:
-
Function diagram:
1510,
2133
P-Group:
Commands
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
0
r0747
CU, digital outputs status / CU DO status
CU
Can be changed:
-
Access level:
1
Data type:
Unsigned32
Data set:
-
Function diagram:
2130,
2131, 2132, 2133
P-Group:
Commands
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...