Parameter list
Parameters
1-265
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Dependency:
Refer to: r1084, r1087, r2197
Note:
For a negative speed limit (r1087) the hysteresis is effective below the limit value and for a positive speed limit
(r1084) above the limit value.
Description:
Sets the speed/velocity threshold value for the "speed setpoint - actual value deviation in tolerance t_off" sig-
nal/message (BO: r2197.7).
Dependency:
Refer to: p2164, p2166, r2197
Description:
Sets the hysteresis speed/velocity (bandwidth) for the "speed setpoint - actual value deviation in tolerance t_off"
signal/message (BO: r2197.7).
Dependency:
Refer to: p2163, p2166, r2197
Description:
Sets the power-off delay time for the "speed setpoint - actual value deviation in tolerance t_off" signal/message
(BO: r2197.7).
Dependency:
Refer to: p2163, p2164, r2197
Description:
Sets the switch-in delay for the "speed setpoint - actual value deviation in tolerance t_on" signal/message (BO:
r2199.4).
Description:
Displays the smoothed actual speed/velocity for messages/signals.
p2163[0...n]
Speed threshold 4 / n_thresh val 4
VECTOR
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
DDS
Function diagram:
8010
P-Group:
Messages
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
0.00 [1/min]
210000.00 [1/min]
90.00 [1/min]
p2164[0...n]
Hysteresis speed 4 / n_hysteresis 4
VECTOR
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
DDS
Function diagram:
8010
P-Group:
Messages
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
0.00 [1/min]
200.00 [1/min]
2.00 [1/min]
p2166[0...n]
Off delay n_act = n_set / t_del_off n_i=n_so
VECTOR
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
DDS
Function diagram:
8010
P-Group:
Messages
Units group:
TIME_M3
Unit selection:
-
Min Max
Factory
setting
0.0 [ms]
10000.0 [ms]
200.0 [ms]
p2167[0...n]
Switch-on delay n_act = n_set / t_del_on n_i=n_so
VECTOR
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
DDS
Function diagram:
8010
P-Group:
Messages
Units group:
TIME_M3
Unit selection:
-
Min Max
Factory
setting
0.0 [ms]
10000.0 [ms]
200.0 [ms]
r2169
CO: Speed actual value smoothed signals / n_act smth message
VECTOR
Can be changed:
-
Access level:
2
Data type:
Floating Point
Data set:
-
Function diagram:
1750,
8010, 8012
P-Group:
Messages
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
- [1/min]
- [1/min]
- [1/min]
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...