Parameter list
Parameters
1-261
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Dependency:
Refer to: p2103, p2103, p2104, p2104, p2105, p2105, p2106, p2106, p2107, p2107, p2108, p2108, p2112, p2112,
p2116, p2116, p2117, p2117
Description:
Displays the first status word of faults and alarms.
Description:
Sets the hysteresis speed/velocity (bandwidth) for the following signals:
"|n_act| < = speed threshold value 2" (BO: r2197.1)
"|n_act| > speed threshold value 2" (BO: r2197.2)
Dependency:
Refer to: p2155, r2197
Description:
Sets the speed/velocity threshold value for the signal "f or n comparison value reached or exceeded" (BO: r2199.1).
Dependency:
Refer to: p2142, r2199
Description:
Sets the hysteresis speed/velocity (bandwidth) for the signal "f or n / v comparison value reached or exceeded"
(BO: r2199.1).
Dependency:
Refer to: p2141, r2199
r2139
CO/BO: Status word faults/alarms 1 / ZSW fault/alarm 1
All objects
Can be changed:
-
Access level:
2
Data type:
Unsigned16
Data set:
-
Function diagram:
1530,
2548
P-Group:
Displays, signals
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
0 signal
1 signal
FP
00
Ackn. running
No
Yes
-
03
Fault present
No
Yes
-
06
Internal message 1 present
No
Yes
-
07
Alarm present
No
Yes
-
08
Internal message 2 present
No
Yes
-
p2140[0...n]
Hysteresis speed 2 / n_hysteresis 2
VECTOR
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
8010
P-Group:
Messages
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
0.00 [1/min]
300.00 [1/min]
90.00 [1/min]
p2141[0...n]
Speed threshold 1 / n_thresh val 1
VECTOR
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
8010
P-Group:
Messages
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
0.00 [1/min]
210000.00 [1/min]
5.00 [1/min]
p2142[0...n]
Hysteresis speed 1 / n_hysteresis 1
VECTOR
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
8010
P-Group:
Messages
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
0.00 [1/min]
300.00 [1/min]
2.00 [1/min]
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...