Parameter list
Parameters
1-85
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Sets the number of pulses for a rotary encoder.
Note:
The number of pole pairs for a resolver is entered here.
The smallest permissible value is 1 pulse.
Description:
Setting to invert actual values.
Note:
The inversion influences the following parameters:
Bit 00: r0061, r0063 (exception: sensorless closed-loop control), r0094
Bit 01: r0482, r0483
Description:
Sets the fine resolution in bits of incremental position actual values for the PROFIBUS encoder interface.
Note:
The parameter applies for the following process data:
- Gx_XIST1
- Gx_XIST2 for reference mark or flying measurement
Description:
Sets the fine resolution in bits of absolute position actual values for the PROFIBUS encoder interface.
Note:
This parameter applies to process data Gx_XIST2 when reading the absolute value.
p0408[0...n]
Rotary encoder pulse No. / Encoder pulse No.
VECTOR
Can be changed:
C2
Access level:
3
Data type:
Unsigned32
Data set:
EDS
Function diagram:
4704,
6004
P-Group:
Encoder
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 16777215
2048
p0410[0...n]
Encoder inversion actual value / Enc inv act value
VECTOR
Can be changed:
T
Access level:
3
Data type:
Unsigned16
Data set:
EDS
Function diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0000 bin
0011 bin
0000 bin
Bit field:
Bit
Signal name
0 signal
1 signal
FP
00
Invert speed actual value
No
Yes
4710,
6010
01
Invert position actual value
No
Yes
4704
p0418[0...n]
Fine resolution Gx_XIST1 (in bits) / Enc fine Gx_XIST1
VECTOR
Can be changed:
C2
Access level:
3
Data type:
Unsigned8
Data set:
EDS
Function diagram:
4704
P-Group:
Encoder
Units group:
-
Unit selection:
-
Min Max
Factory
setting
2 18
11
p0419[0...n]
Fine resolution absolute value Gx_XIST2 (in bits) / Enc fine Gx_XIST2
VECTOR
Can be changed:
C2
Access level:
3
Data type:
Unsigned8
Data set:
EDS
Function diagram:
4704
P-Group:
Encoder
Units group:
-
Unit selection:
-
Min Max
Factory
setting
2 18
9
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...